Z-Wave Plus 700-series Programmable Thermostat (2GIG-STZ-1) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Z-Wave Plus 700-series Programmable Thermostat (2GIG-STZ-1)from 2GIG. To view other Z-Wave products and manuals from 2GIG follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
2GIG Z-Wave Plus 700-series Programmable Thermostat
SKU Code
2GIG-STZ-1
Description
2GIG-STZ-1 Z-Wave Plus Thermostat is the latest programmable, Z-Wave thermostat from Nortek, enabling end users to manage the thermostat, configure programming settings, as well as to display current conditions in the home or office. The thermostat can support up to three heat and two cool stages of heap pump and conventional HVAC systems, including humidification support. It can be powered using 24VAC or using four (4) AA batteries. Comes With S2 Security and OTA capability.
Version #
HW: 1 FW: 1.08:03.07 was the version certified
Certification #
ZC12-21030203
Certified
2021-03-19T12:33:55.073261
Z-Wave Version
7.12.2

Security

As a Z-Wave Plus certified product, Z-Wave Plus 700-series Programmable Thermostat supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

2GIG describes Z-Wave Plus 700-series Programmable Thermostat as having the following features:

  • Firmware updatable via a compatible Z-Wave gateway
  • Thermostat HVAC Systems Supported
  • Thermostat Modes
  • Thermostat Power Source
  • Battery Quantity
  • Battery powered using AA Alkaline battery batteries
  • Color
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: "Note: The S2 DSK string, pin code, and QR code are printed on a label above the LCD screen under
the faceplate."

"1. Set your primary controller to Include, add or Install mode, to add the thermostat as a node on
your network (see your controller’s user manual for detailed instructions).
2. Touch any button to take the thermostat out of sleep mode.
3. Touch and hold MODE button for 5 seconds. SETUP will be displayed in the status display line.
4. Scroll to “Z-Wave” using  buttons. Touch FAN (Select).
5. When prompted by your Z-Wave controller, select YES in the Z-Wave Install screen.
6. Touch FAN (Select) to add thermostat to network.
7. The display line should flash WAIT and then SUCCESS if Z-Wave connection is made.
8. If Z-Wave does not connect to controller, WAIT, then FAIL will flash in status display line.
9. If thermostat fails to connect, repeat Steps three (3) through (7) to re-try connecting.
Your controller will indicate the thermostat was successfully added to its network (see your
controller’s user manual for details). Also, you can check if the thermostat was successfully added
to the network by checking the ZHID (Home ID) and ZNID (Node ID) located in the thermostat INFO
screen."

Removing from a Z-Wave Network
To remove the thermostat from the network, use the following steps.
1. Set your primary controller to exclude or remove mode to remove the thermostat as a node on
your network (see your controller’s user manual for detailed instructions).
2. Touch any button to take the thermostat out of sleep mode.
3. Touch and hold the MODE button for 5 seconds. SETUP will be displayed in the status display line.
5. Scroll to “Z-Wave” using  buttons. Touch FAN (Select).
6. When prompted by your Z-Wave controller, select YES in the Z-Wave exclude screen.
7. Touch FAN (Select) to remove thermostat to network.
8. The display line should flash WAIT then SUCCESS if the thermostat is removed from the network.
9. If the removal operation is not successful, WAIT will flash, then FAIL will flash in status display
line. Repeat Steps three (3) through (7) to re-try.

Wake-Up Command Class not used in the project, no need to input wake-up procedure.

Factory reset Z-Wave Plus 700-series Programmable Thermostat

Factory Reset
WARNING: Please use this procedure only when the Z-Wave Primary Controller is
missing or otherwise inoperable.
To reset the 2GIG-STZ-1's Z-Wave parameters to Factory Settings (both Z-Wave and HVAC settings):
1. Touch and hold MODE button to go to Setup menu.
2. Touch and hold MODE and the down arrow key to enter Advanced Menu.
3. Navigate to Restore Defaults to perform a factory reset.

Please note that this is a user manual Z-Wave Plus 700-series Programmable Thermostat from 2GIG is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-Wave Plus 700-series Programmable Thermostat and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.