DSC Panel Radio Module (AUS) (ADC-620T (AUS)) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product DSC Panel Radio Module (AUS) (ADC-620T (AUS))from Alarm.com. To view other Z-Wave products and manuals from Alarm.com follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Alarm.com DSC Panel Radio Module (AUS)
SKU Code
ADC-620T (AUS)
Description
Alarm.com DSC Panel Radio Module for Australia/New Zealand
Version #
HW: 103 FW: 4.32:03.13 was the version certified
Certification #
ZC10-18126334
Certified
2018-12-13T01:26:05.513004
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, DSC Panel Radio Module (AUS) supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Alarm.com describes DSC Panel Radio Module (AUS) as having the following features:

    • Firmware updatable via a compatible Z-Wave gateway
    • Sensors
    • Supported Notification Types
    • Gateway Has Preferred Partners
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    1 Adding devices to the Alarm.com ADC-620T’s Z-Wave Network
    NOTE: This process leverages Network Wide Inclusion. In addition, any controllers added to the Alarm.com ADC-620T will have network information replicated over to them.
    1. Using Mobiletech
    a. Install the MobileTech App (if not already done) and select the customer of interest.
    b. Move all Z-Wave devices to their final location on the property.
    c. Navigate to the Equipment List page.
    d. Select emPower Management.
    e. Select Add Z-Wave Devices
    f. Wait for the bolded message: Checking for new devices on the network
    g. Trigger a device to add it to the network.
    h. When a device is added successfully, it will show up on this screen following a 30 second delay.
    i. Continue triggering devices. You may add many devices to the network without reentering Add Mode.
    2. Using the Dealer Website
    a. Navigate to the Equipment page.
    b. Click the emPower Devices tab.
    c. Open the Advanced Z-Wave Commands menu below the Equipment List.
    d. Click Add Z-Wave Devices.
    e. Wait for the bolded message: Checking for new devices on the network.
    f. Trigger a device to add it to the network.
    g. When a device is added successfully, it will show up on this screen following a 30 second delay.
    h. Continue triggering devices. You may add many devices to the network without reentering Add Mode.
    3. Using the DSC Panel
    a. Press [*] [8], then the installer code, to enter Installer Programming.
    b. Enter 851 for Interactive Services.
    c. Use the arrow keys to scroll to and select Z-Wave Setup.
    d. Use the arrow keys to scroll to and select Add Z-Wave Device.
    e. Trigger a device to add it to the network.
    f. When a device is added successfully, the panel will beep.
    g. You will need to re-enter Add Mode before triggering the next device.

    2 Removing devices from the Alarm.com ADC-620T’s Z-Wave network
    1. Using Mobiletech
    a. Install the MobileTech App (if not already done) and select the customer of interest.
    b. Move all Z-Wave devices you plan to remove close to the Alarm.com ADC-620T.
    c. Navigate to the Equipment List page.
    d. Select emPower Management.
    e. Select remove Z-Wave Devices
    f. Wait for the bolded message: Checking for removed devices on the network
    g. Trigger a device to remove it from the network.
    h. When a device is removed successfully and its network information is erased, it will show up on this screen following a 30 second delay.
    i. Continue triggering devices. You may remove many devices to the network without reentering remove Mode.
    2. Using the Dealer Website
    a. Move all Z-Wave devices you plan to remove close to the Alarm.com ADC-620T.
    b. Navigate to the Equipment page.
    c. Click the emPower Devices tab.
    d. Open the Advanced Z-Wave Commands menu below the Equipment List.
    e. Click remove Z-Wave Devices.
    f. Wait for the bolded message: Checking for removed devices on the network.
    g. Trigger a device to remove it from the network.
    h. When a device is removed successfully and its network information is erased, it will show up on this screen following a 30 second delay.
    i. Continue triggering devices. You may remove many devices to the network without reentering remove Mode.
    3. Using the DSC Panel
    a. Press * then 8 to enter Installer Programming.
    b. Enter 851 for Interactive Services.
    c. Use the arrow keys to scroll to and select Z-Wave Setup.
    d. Use the arrow keys to scroll to and select Remove Z-Wave Device.
    e. Trigger a device to clear its network data and remove it from the existing Z-Wave network.
    f. The panel will beep when a device has been removed.
    g. You will need to re-enter remove Mode to remove more devices.

    4 Learning the Alarm.com ADC-620T into another Z-Wave network
    1. Learning in the Alarm.com ADC-620T using the Dealer Site
    a. Log in to the Alarm.com Dealer Site
    b. Select the customer whose node you wish to remove
    c. Navigate to the page to allow sending generic commands. This can be found in the AirFX Remote Toolkit or by navigating to https://alarmadmin.alarm.com/Support/Commands/GenericCommand.aspx
    d. Place a controller on the existing network into add mode
    e. Send the generic command 5B10030101 to the ADC-620T, once received it will cause the Alarm.com ADC-620T to learn into the existing Z-Wave network and will allow it to cause all relevant network information to be copied over from the controller that was put into add mode.

    Support for the Wake Up command class is enabled using Alarm.com’s rules engine. This requires a series of rules pushed from the cloud when Alarm.com detects that a Wake Up device has been added to the Alarm.com Module.
     For this reason Wake Up notifications will only be handled properly by the Alarm.com module after any locally added Wake Up devices have been reported to the backend. This can take up to 15 minutes, but can be accelerated by using Remote Add or by requesting a Z-Wave Equipment List from the Alarm.com backend.

    Factory reset DSC Panel Radio Module (AUS)

    Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.

    NOTE: This function will forcibly clear the Alarm.com ADC-620T’s Z-Wave node identification and will also remove all network information from the ADC-620T. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable
    1. A Z-Wave factory reset must be triggered from the Alarm.com dealer site
    2. Navigate to the Equipment page.
    3. Click the “emPower Devices” tab.
    4. Open the “Advanced Z-Wave Commands” menu by clicking the button below the Equipment List.
    5. Towards the bottom next to the “Equipment List Label” text click on the “Reset To Factory Default” button
    6. Allow 3 minutes for the associated commands to go through and for the ADC-620T to act on them

    Please note that this is a user manual DSC Panel Radio Module (AUS) from Alarm.com is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have DSC Panel Radio Module (AUS) and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.