Smart Noise Monitor (Sigma Nu) (ADC-N10-N) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Smart Noise Monitor (Sigma Nu) (ADC-N10-N)from Alarm.com. To view other Z-Wave products and manuals from Alarm.com follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Smart Noise Monitor (Sigma Nu)
SKU Code
ADC-N10-N
Description
Noise Monitor sensor that measures detected audio levels. Indoor Use Only.
Version #
HW: 01 FW: 00.49:00.51 was the version certified
Certification #
ZC14-22110168
Certified
2022-11-21T15:26:53
Z-Wave Version
7.17.2

Security

As a Z-Wave Plus certified product, Smart Noise Monitor (Sigma Nu) supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Alarm.com describes Smart Noise Monitor (Sigma Nu) as having the following features:

  • Firmware updatable via a compatible Z-Wave gateway
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: The SmartStart DSK is located on the back label of the Noise Sensor device.

1.1 Adding the Noise Sensor to a Z-Wave network
1. Put Z-Wave controller into Add mode. See Z-Wave controller documentation for further information.
2. Press the pairing button on the side of the control unit. The LED will begin to blink green.
3. The unit has been successfully added to the network when the LED becomes solid green.

1.2 Removing the Noise Sensor from a Z-Wave network
1. Put Z-Wave controller into Remove mode. See Z-Wave controller documentation for further documentation.
2. Press the pairing button on the side of the control unit. The LED will begin to blink green.
3. The unit has been successfully removed from the network when the LED turns off.

Factory reset Smart Noise Monitor (Sigma Nu)

1. Press and hold the pairing button on the side of the control unit 15 seconds. The LED will then alternate red and green until the button is released, at which point the reset process will begin.
2. The device will first send a Device Reset Locally notification, which notifies the controller that it should be removed from the Z-Wave network
3. Once the device has been reset, the LEDs will return to their normal state.
4. Device reset will reset NVM, EEPROM, and the Z-Wave chip.

Please note that this is a user manual Smart Noise Monitor (Sigma Nu) from Alarm.com is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Smart Noise Monitor (Sigma Nu) and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.