SmartLock (ZSL10) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product SmartLock (ZSL10)from Atsumi Electric Co.,Ltd.. To view other Z-Wave products and manuals from Atsumi Electric follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
SmartLock
SKU Code
ZSL10
Description
This product "ZSL10" can remotely lock and unlock the door and check the status by remote control.
Version #
HW: 1 FW: 4.01:01.67:01.35 was the version certified
Certification #
ZC12-20110130
Certified
2020-11-05T15:03:58.956115
Z-Wave Version

Security

As a Z-Wave Plus certified product, SmartLock supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Access Control

Features

Atsumi Electric describes SmartLock as having the following features:

  • Battery Quantity
  • Battery powered using AA type(alkaline or lithium) batteries
  • Door Lock Type
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: QR code and Full DSK is located inside the battery box of IN-BODY and on the packing box.

Set the controller in “Add(Inclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation and the O / C button will blink blue and beeps twice.
Inclusion takes about 1 minute. Please confirm the inclusion is complete.
After that, it flashes red, but this is not related to the success / failure of inclusion.

Set the controller in “Remove(Exclusion)” mode.
For the operation procedure, see the instruction manual of the controller.
Press the SET button for about 5 seconds to start the registration operation and the O / C button will blink blue and beeps twice. Please confIrm the inclusion is complete.
After that, it flashes red, but this is not related to the success / failure of inclusion.

Factory reset SmartLock

Use this procedure only in the event that the primary controller is lost.
The controller information are cleared.
The lock settings and user information do not change.
Press the SET button three times in two seconds to start the reset operation and the O/C button will blink red and beeps.

none

Please note that this is a user manual SmartLock from Atsumi Electric Co.,Ltd. is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have SmartLock and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.