Alert Button (T8343) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Alert Button (T8343)from Axis Communications . To view other Z-Wave products and manuals from Axis follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Alert Button
SKU Code
T8343
Description
AXIS T8343 Alert Button is a wireless push button which relays events such as notification messages, illumination and much more. With its support for wireless input/output connectivity, the alert button can communicate wirelessly with AXIS M5065 PTZ Network camera or other connected Z-Wave PlusĀ® controllers, creating a small security solution with less cabling. Thanks to its integrated wireless I/O connectivity, AXIS T8343 enables flexible installation as the relay can easily be moved and adapted to your needs.
Version #
HW: 1 FW: 1.01:00.01 was the version certified
Certification #
ZC10-17115879
Certified
2017-11-22T04:40:26.066534
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, Alert Button supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Axis describes Alert Button as having the following features:

  • Battery Quantity
  • Battery powered using AAA batteries
  • Color
  • Firmware updatable via a compatible Z-Wave gateway
  • Supported Notification Types
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

1. Put the Z-Wave Controller into inclusion mode.
2. Press the link button 3 times within 1.5 seconds to put the unit into inclusion mode.

1. Put the Z-Wave Controller into exclusion mode.
2. Press the link button 3 times within 1.5 seconds to put the unit into exclusion mode.

After it has been included into a Z-wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life.

The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:

Minimum Wake Up Interval 600s (10 minutes)
Maximum Wake Up Interval 86400s (1 day)
Default Wake Up Interval 14400s (4 hours)
Wake Up Interval Step Seconds 600s (10 minutes)

Factory reset Alert Button

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

1. Press the link button 3 times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press the link button again and hold for 5 seconds.
3. Node ID is excluded. The device reverts to factory default state.

Please note that this is a user manual Alert Button from Axis Communications is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Alert Button and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.