  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Beanbag Thermostat Receiver
SKU Code
MAX10Z-737
Description
The Beanbag receiver is a wireless two-channel thermostat / programmer, which can be used to control the heating and hot water system. Channel 1 is used for heating with Channel 2 being used for heating or hot water. Contact rating is 3A 230V AC, 1 A reactive. The receiver is mains powered 230V AC 50Hz only. A 7 day schedule facility is possible; each day can have different times and temperatures. TPI control is provided for Gas, Oil or Electrical Boilers with 3, 6 or 9 cycles per hour respectively. A one day override (on or off) facility is provided for heating and hot water. Thermostat failsafe is covered with the provision of a backup temperature sensor. The receiver is wall mounted using a plate with an optional facia plate; it is push on / pull off with the provision of a safety cover to ensure no mains access when removed. An optional surface wiring plate is also provided. Enclosure protection is to IP30 with an operating temperature range of 0⁰C to 40⁰C.
Version #
HW: 2 FW: 2.00 was the version certified
Certification #
ZC10-17055592
Certified
2017-05-17T22:30:09.5681
Z-Wave Version
6.61.00

Security

As a Z-Wave Plus certified product, Thermostat Receiver supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Beanbag describes Thermostat Receiver as having the following features:

    • Switch Type
    • Switch Load Capacity Current
    • Loads Controlled
    • Thermostat Modes
    • Color
    • Neutral Wire Required
    • Firmware updatable via a compatible Z-Wave gateway
    • Thermostat HVAC Systems Supported
    • Sensors
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Thermostat Receiver

    Long press the bottom button (located underside the unit) for around 4 Sec until the Network indicator LED turns red then release the button.

    This function should only be used in case of primary controller is missing or inoperable.

    1. The product supports dynamic endpoint configuration for Thermostat or Switch at endpoint 2.

    2. Learning algorithm used to track the temperature in case if primary sensor is not communicating.

    1. Put network controller in Exclusion mode.
    2. Hold the button on the top of the Beanbag Receiver for more than 2 seconds until the Network Indicator LED turns red then release the button to put the Beanbag Receiver into Learn Mode.
    3. Beanbag Receiver will indicate success with flashing white Network LED (3Sec ON and 30Sec OFF).

    1. Put network controller in Inclusion mode.
    2. Hold the button on the top of the Beanbag Receiver for more than 2 seconds until the Network Indicator LED turns red then release the button to put the Beanbag Receiver into Learn Mode.
    3. Beanbag Receiver will indicate success with sold white Network LED.

    Please note that this is a user manual Thermostat Receiver from Beanbag is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Thermostat Receiver and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.