Meta Double Switch-l 7 (A510083) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Meta Double Switch-l 7 (A510083)from Cherubini. To view other Z-Wave products and manuals from Cherubini follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
META DOUBLE SWITCH-L 7
SKU Code
A510083
Description
META Double Switch -L 7 is an ON/OFF control device designed to independently control two separate loads, suited for being controlled by both remote and local switches.
Version #
HW: 01 FW: 02.01 was the version certified
Certification #
ZC14-22120174
Certified
2022-12-06T13:37:59
Z-Wave Version
7.16.3

Security

As a Z-Wave Plus certified product, Meta Double Switch-l 7 supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Cherubini describes Meta Double Switch-l 7 as having the following features:

  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: Page 38 - The SmartStart QR and the full DSK string code can be found on the back of the device. The PIN is the first group of 5 digits printed underlined. If you plan to use the DSK, it is important that you take a picture of the label and keep it in a safe place.

All META Serie 7 devices are compatible with all Z-Wave™/Z-Wave Plus™ certified controllers. The devices support both the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Normal Inclusion.
By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout the procedure continues in Network Wide Inclusion mode that lasts for about 20 Seconds.
Only a controller can add the device into the network. After activating the inclusion function by the controller, the device can be added by setting it in Learn Mode.

Only a controller can remove the device from the network. After activating the exclusion function by the controller, the device can be removed by setting it in Learn Mode.
The procedure of exclusion can be activated by Removing a node from the Z-Wave™ network and executing 1 or 3 click on the integrated button; as soon as the exclusion initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded from the network when the LED status indicator is solid RED and the App_status in the interface is OK.

Factory reset Meta Double Switch-l 7

Reset to the factory settings
The device can be reset to the original factory settings with 6 consecutive clicks on the integrated button.
After the reset is completed, the device will reboot and a RED solid led is showed.

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that it has been removed (Device Reset Locally Notification).

Timer Management
An independent timer for each channel can be set when switching On and/or Off. It also possible to define which event will start the timer (for example only the change on the output due to double clicks).

Power consumption management
The device is equipped with a very precise power metering functionality, therefore you can easily monitor the instantaneous power and cumulated energy for each channel.

Offline setup Mode
The device has a unique feature that allows to configure some parameters without using any user interface. This feature enables the professional user to setup the main features of the device in the field even if the device is not included in a Z-Wave™ Network. When the device will be included in the network all these configuration parameters will be maintained.

Central Scene Notification
Supports Central Scene Notification all the events described in the table will be notified with a Central Scene Notification Report to the Lifeline. The events that trigger a Central Scene Notification Report can be customized with the configuration parameter in the Central Scene Notification Parameter section.

Please note that this is a user manual Meta Double Switch-l 7 from Cherubini is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Meta Double Switch-l 7 and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.