The following is an overview of the user manual for the Z-Wave product Energy Meter (EMD-1ZW)from Climax Technology. To view other Z-Wave products and manuals from Climax Technology follow that link.
Overview
Security
As a Z-Wave Plus certified product, Energy Meter supports Z-Wave S2 security. The following security modes are directly supported:
Features
Climax Technology describes Energy Meter as having the following features:
- Supported Meter Type
- Battery Quantity
- Battery powered using Alkaline Batteries AA batteries
- Firmware updatable via a compatible Z-Wave gateway
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
-Insert batteries to power on the E-meter.
-Put the Z-Wave control panel into Inclusion mode (please refer to
the Z-Wave control panel manual).
-Within 1.5 seconds, press the Function Button 3 times.
-Refer to operation manual of the Z-Wave Gateway or Control Panel
to complete the adding process.
If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).
The device must be removed from existing Z-Wave network before being added into another.
Exclusion Mode
-Put the Z-Wave Gateway or Control Panel into Exclusion mode
(please refer to the Z-Wave or control panel manual).
-Within 1.5 seconds, press the Function Button 3 times and the
device will be removed from the Z-Wave network.
Factory reset Energy Meter
Factory resetting the device will restore it to factory default settings (i.e. not included into any Z-Wave network). Please only use this procedure if the Z-Wave Gateway or Control Panel is lost or otherwise inoperable.
-Press and hold the Function Button of the device for 10 seconds to
factory reset.
Please note that this is a user manual Energy Meter from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Energy Meter and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.