The IRP-16SL ZW is a Z-Wave motion detector that senses and reports suspicious movements to a security or home automation system. This microprocessor-controlled sensor adopts Adaptive Digital Signal Processing (ADSP) algorithms to deliver sensitive and reliable detection. It provides pet immunity up to 27 kilos (59 lbs) to eliminate false alarms caused by animals.
The lithium battery-powered IRP-16SL ZW features long battery life of three years. Compatible with any Z-Wave mesh networks and devices, the IRP-16SL ZW can be flexibly incorporated into Z-Wave enabled systems for residential or commercial applications.
Version #
HW: 1 FW: 1.03:01.02 was the version certified
Certification #
ZC10-16115317
Certified
2016-11-28T16:50:04.250029
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Motion Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Climax Technology describes Motion Sensor as having the following features:

    • Battery Quantity
    • Battery powered using CR123 batteries
    • Firmware updatable via a compatible Z-Wave gateway
    • Sensors
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Motion Sensor

    Factory Reset
    Factory resetting the device will restore it to factory default settings (i.e. not included into any Z-Wave network). Please only use this procedure if the Z-Wave gateway or control panel is lost or otherwise inoperable.
    - Press and hold the Function Button of the device for 12 seconds to factory reset.

    This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered PIR to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up interval time period is programmed automatically according to Control Panel’s setting when The PIR is included. The recommended setting of the interval time is between 30 to 60 minutes.

    The device must be removed from existing Z-Wave network before being added into another.
    Exclusion Mode
    - Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave or control panel manual).
    - Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-Wave network.

    This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
    - Pull out the battery Insulator steadily.
    - The LED indicator will flash for 30 seconds (The PIR is warming up). During the warm up period, the PIR will not be activated. It is recommended that you stay away from the detection area during this time. After the warming period is over, the LED will turn off and the PIR will be ready for operation.
    - Put the Z-Wave control panel into Inclusion mode (please refer to the Z-Wave control panel manual).
    - Within 1.5 seconds, press the Function Button 3 times.
    - Refer to the operation manual of the Z-Wave gateway or control panel to complete the adding process.
    - Please press and release the Tamper Switch once after inclusion is completed to ensure the Gateway/Control Panel recognizes the current Tamper condition.
    - If the device has already been added (included) into another Z-Wave Gateway/Control Panel, or if the device is unable to be added into the current Z-Wave Gateway/Control Panel, try removing it first (see Removing Device).

    Please note that this is a user manual Motion Sensor from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Motion Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.