Name
Smoke Detector
SKU Code
SD-29
Description
The SD-29 is a wirelessly operated photo-electronic Smoke Detector designed to operate with any Z-Wave enabled controller devices; it also features smoke detecting, temperature sensing and IR detection. The Smoke Detector’s alarm situations, battery condition, operating conditions, supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected with other sensors in the Z-Wave gateway to serve as an extra siren.
Version #
HW: 255 FW: 4.01 was the version certified
Certification #
ZC10-20046908
Certified
2020-04-29T07:34:39.674537
Z-Wave Version
6.81.06

Security

As a Z-Wave Plus certified product, Smoke Detector supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Climax Technology describes Smoke Detector as having the following features:

  • Battery powered using CR123 batteries
  • Firmware updatable via a compatible Z-Wave gateway
  • Battery Quantity
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

1. Insert three 3V CR123 Lithium batteries into the battery compartment. Orient the battery according to the battery compartment polarity indication before insertion.
2. After batteries are inserted, the Smoke Detector will sound 2 short beeps, the Red LED will start to flash and initiates a 1-minute warm-up period.
3. During the 1-minute warming period, you can learn (include) the Smoke Detector into the Panel, refer to Add Device (Inclusion) for details.
4. Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual).
5. Within 1.5 seconds, press the Function button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds. Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process.
6. When the 1-minute warming period is over, one short beep will sound to indicate that the Smoke Detector is starting calibration process. Learning/Inclusion is prohibited during calibration. If the Smoke Detector has not been included in the panel yet, wait for calibration to complete before including the Smoke Detector. The completion of calibration process will be notified by a 2-tone beep and the Red LED will turn off. If the Smoke Detector gives out continuous beeps instead, it indicates that the Smoke Detector has failed the calibration. Remove the battery and restart from step 1 after a pause of at least 30 seconds.
7. After the warming-up and calibration process, if the Smoke Detector is not learned (included) into the Z-Wave gateway/Control Panel, complete the learning/inclusion process then refer to Installation section below to mount the Smoke Detector.
8. If the sensor has already been included (learnt) into another Z-Wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-Wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-Wave Gateway/Control Panel.

1. Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).
2. Within 1.5 seconds, press the Function button 3 times and the Smoke Detector will be removed from the Z-Wave network.

Factory reset Smoke Detector

(Only use factory reset when network Control Panel/Gateway is missing or inoperable).
*. Press and hold the button of the smoke detector for 20 seconds. Release the button when you hear 3 beeps to perform factory reset.

Listening Sleeping Slave (LSS)

Please note that this is a user manual Smoke Detector from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Smoke Detector and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.