Smoke Detector (SD-8ZW) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Smoke Detector (SD-8ZW)from Climax Technology. To view other Z-Wave products and manuals from Climax Technology follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Smoke Detector
SKU Code
SD-8ZW
Description
The SD-8ZW is a Z-Wave smoke detector with a built-in siren to sound audible alerts when alarms occur. The SD-8ZW triggers alarms by using latest optical chamber technology to detect harmful smoke particles enter its detection chamber.
Version #
01 was the version certified
Certification #
ZC10-15080007
Certified
2015-08-10T14:18:31.8424
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Smoke Detector supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Climax Technology describes Smoke Detector as having the following features:

    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    The Smoke Detector must be removed from existing Z-wave network before being included into another. There are two methods available to exclude a device.
    Exclusion Mode
    -Put the Z-wave gateway or control panel into Exclusion mode (please refer to the Z-wave gateway or control panel manual).
    -Within 1.5 seconds, press the Test Button 3 times and the Smoke Detector will be removed from the Z-wave network.

    This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
    -Insert the 3 “AA” batteries into the battery compartment connecting the correct polarity as shown on the battery compartment lid. The Smoke Detector will emit a 2-tone beep.
    -The LED will start flashing and begin a 6-minute warming period.
    -Put the Z-wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-wave gateway or control panel manual).
    -Within 1.5 seconds, press the Test Button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will turn on for ~2 seconds.
    -Refer to the operation manual of the Z-wave gateway or control panel to complete the learn-in process.
    -If the sensor has already been included (learnt) into another Z-wave Gateway/Control Panel, or if the sensor is unable to be learnt into the current Z-wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-wave Gateway/Control Panel.
    -When the 6-minute warming period is over, the Smoke Detector will emit one short beep to indicate that the Smoke Detector is starting calibration process. The process will be repeated every 100 seconds and notified by a short beep respectively. The Smoke Detector will emit a 2-tone beep and the LED will turn off to indicate calibration is completed.
    -Normal calibration process lasts 2 - 16 minutes.
    -If the Smoke Detector emits continuous beeps after 16 minutes, the calibration has failed. Remove the batteries to silence the continuous beeps.
    -Restart the calibration process by re-inserting the batteries.

    This function uses the Z-Wave Wake Up Command Class. The Wake Up Command Class allows the battery-powered Heat Detector to notify the Control Panel/Gateway that it is awake and ready to receive any queued commands. The wake up interval time period is programmed automatically according to Control Panel’s setting when The Heat Detector is included. The recommended setting of the interval time is between 30 to 60 minutes.

    Factory reset Smoke Detector

    (Only use factory reset when network Control Panel/Gateway is missing or inoperable).
    -Press and hold the Test Button of the Smoke Detector for 8 seconds to factory reset.

    Please note that this is a user manual Smoke Detector from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Smoke Detector and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.