The following is an overview of the user manual for the Z-Wave product Srac-23zw (SRAC-23ZW)from Climax Technology. To view other Z-Wave products and manuals from Climax Technology follow that link.
Overview
Security
As a Z-Wave Plus certified product, Srac-23zw supports Z-Wave S2 security. The following security modes are directly supported:
Features
Climax Technology describes Srac-23zw as having the following features:
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
The Siren must be removed from existing Z-Wave network before being included into another. There are two methods available to exclude a device.
Exclusion Mode
-Put the Z-Wave gateway or control panel into Exclusion mode (please refer to the Z-Wave gateway or control panel manual).
-Within 1.5 seconds, press the Test Button 3 times and the Siren will be removed from the Z-Wave network.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufactures and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
-Plug the Siren into a power socket.
-The LED indicator will flash twice.
-Put the Z-Wave gateway or control panel into Inclusion or Learning mode (please refer to the Z-Wave gateway or control panel manual).
-Within 1.5 seconds, press the Test Button 3 times.
-Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in process.
-If the Siren was included successfully, it will emit 1 long beep and the LED will flash once.
-If the device has already been included (learnt) into another Z-Wave Gateway/Control Panel, or if the device is unable to be learnt into the current Z-Wave Gateway/Control Panel, please exclude it first (see Exclusion) before attempting to include it into the current Z-Wave Gateway/Control Panel.
Factory reset Srac-23zw
Factory Reset
(Only use factory reset when network Control Panel/Gateway is missing or inoperable).
-Press and hold the Test Button of the Siren for ~10 seconds until the LED starts to flash (twice) to factory reset. The siren will also emit 2 short beeps.
Please note that this is a user manual Srac-23zw from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Srac-23zw and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.