Z-Wave Motion Sensor (IR-16ZW) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Z-Wave Motion Sensor (IR-16ZW)from Climax Technology. To view other Z-Wave products and manuals from Climax Technology follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Z-Wave Motion Sensor
SKU Code
IR-16ZW
Description
The IR-16ZW is a Z-Wave motion detector sensing and reporting suspicious movements to a security or home automation system. Compatible with any Z-Wave mesh networks and devices, the IR-16ZW can be flexibly incorporated into Z-Wave enabled systems for residential or commercial applications.

The IR-16ZW adopts advanced Adaptive Digital Signal Processing (ADSP) algorithms to deliver sensitive and reliable detection. Powered by a pre-inserted lithium battery, the IR-16ZW features long battery life .
Version #
01 was the version certified
Certification #
ZC10-15050009
Certified
2015-05-12T08:29:45.4096
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Z-Wave Motion Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Climax Technology describes Z-Wave Motion Sensor as having the following features:

    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Z-Wave Motion Sensor

    Factory resetting the device will restore it to factory default settings (i.e. not included into any Z-wave network). Please only use this procedure if the Z-Wave gateway or control panel is lost or otherwise inoperable.
    - Press and hold the Function Button of the device for 12 seconds to factory reset.

    1. Put the Z-wave gateway or control panel into Exclusion mode (please refer to the Z-wave or control panel manual).
    2. Within 1.5 seconds, press the Function Button 3 times and the device will be removed from the Z-wave network.

    1. Pull out the battery Insulator steadily.
    2. The LED indicator will flash for 30 seconds (The PIR is warming up). During the warm up period, the PIR will not be activated. It is recommended that you stay away from the detection area during this time. After the warming period is over, the LED will turn off and the PIR will be ready for operation.
    3. Put the Z-wave control panel into Inclusion mode (please refer to the Z-wave control panel manual).
    4. Within 1.5 seconds, press the Function Button 3 times.
    5. Refer to the operation manual of the Z-wave gateway or control panel to complete the adding process.
    6. Please press and release the Tamper Switch once after inclusion is completed to ensure the Gateway/Control Panel recognizes the current Tamper condition.
    7. If the device has already been added (included) into another Z-wave Gateway/Control Panel, or if the device is unable to be added into the current Z-wave Gateway/Control Panel, try removing it first (see Removing Device).

    1. Pull out the battery Insulator steadily.
    2. The LED indicator will flash for 30 seconds (The PIR is warming up). During the warm up period, the PIR will not be activated. It is recommended that you stay away from the detection area during this time. After the warming period is over, the LED will turn off and the PIR will be ready for operation.
    3. Put the Z-wave control panel into Inclusion mode (please refer to the Z-wave control panel manual).
    4. Within 1.5 seconds, press the Function Button 3 times.
    5. Refer to the operation manual of the Z-wave gateway or control panel to complete the adding process.
    6. Please press and release the Tamper Switch once after inclusion is completed to ensure the Gateway/Control Panel recognizes the current Tamper condition.
    7. If the device has already been added (included) into another Z-wave Gateway/Control Panel, or if the device is unable to be added into the current Z-wave Gateway/Control Panel, try removing it first (see Removing Device).

    Please note that this is a user manual Z-Wave Motion Sensor from Climax Technology is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-Wave Motion Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.