The following is an overview of the user manual for the Z-Wave product 4-Channel Power Strip (CT4R)from CONFIO. To view other Z-Wave products and manuals from CONFIO follow that link.
Overview
It has the following features
• Four Relay switches enable ON/OFF control of Regular loads.
• Typical Regular relay loads (4R) are light sources (incandescent bulbs, CFL, LED lamps… etc), heaters, fans, air-conditioners, fridges, door openers, and other utility appliances.
• The Quad switch CT4R also operates as a repeater within the Z-Wave network it is associated with.
Security
As a Z-Wave Plus certified product, 4-Channel Power Strip supports Z-Wave S2 security. The following security modes are directly supported:
- S2 Unauthenticated
Features
CONFIO describes 4-Channel Power Strip as having the following features:
- Firmware updatable via a compatible Z-Wave gateway
- Loads Controlled
- Neutral Wire Required
- Switch Load Capacity Current
- Switch Load Capacity Volt-Ampere
- Switch Load Capacity Watts
- Electric Load Type
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
Factory reset 4-Channel Power Strip
Device Reset can be invoked by press & hold NODE_INFO key for more than 10 seconds. User indication: Blinking of red LED shows a successful reset. The controller will be informed about this event via COMMAND_CLASS_DEVICE_RESET_LOCALLY command.
Once the device resets, it will no longer be a part of the Z-Wave network and all the user configuration parameters are set to their default values.
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
The term “INCLUSION”, “ADDING”, “PARING” implies the same meaning. Inclusion is a process by which a new device (or a device which previously got out of Z-Wave network by force reset or exclusion process) can join a new or existing Z-Wave network.
Basically, two steps are involved in the inclusion process,
1) Set Gateway/Controller into the inclusion mode (See gateway user manual)
2) Set device into the learn mode
Learn mode can be invoked by a one-time short press of NODE_INFO key or three times ON press (within 5 seconds) of S1 key.
User indication: Blinking of green LED shows successful inclusion.
The term “EXCLUSION”, “REMOVING”, “UNPAIRING” implies the same meaning. Exclusion is a process by which an already included device can be made to leave its existing Z-Wave network. Upon exclusion, all user configuration parameters are set to their default values.
Exclusion of the device can be done in two steps,
1) Set Gateway/Controller into the exclusion mode (See gateway user manual)
2) Set device into the learn mode
Learn mode can be invoked by a one-time press of NODE_INFO key or three times ON press (within 5 seconds) of S1 key.
User indication: Blinking of red LED shows successful exclusion.
Support ""Over the Air Firmware Updating"" and “Z-Wave Security”.
Please note that this is a user manual 4-Channel Power Strip from CONFIO is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 4-Channel Power Strip and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.