The following is an overview of the user manual for the Z-Wave product Door Sensor (NAS-DS01Z)from Coolcam. To view other Z-Wave products and manuals from Coolcam follow that link.
Overview
Two status: open and close
Compatible with 300 series and 500 series
Power: CR14250 x1
Standby current: 1uA
Battery life: 10 years
Install on the door or window
Easily install with screws or sticker.
Operation temperature: 0-40℃
Size: Main body (L x W x H): 70mmx20mmx20mm
Deputy body (L x W x H): 40mmx11mmx11mm
Security
As a Z-Wave Plus certified product, Door Sensor supports Z-Wave S2 security. The following security modes are directly supported:
Features
Coolcam describes Door Sensor as having the following features:
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
Add the Sensor (Door/Window detector) to Z-Wave Network
1.Remove the sensor cover.
2.Make sure the sensor is powered.
3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Delete the Sensor (Door/Window detector) from Z-Wave Network
1.Remove the device cover.
2.Make sure the sensor is powered.
3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
4.Press the button three times within 1.5 second, the device will enter exclusion mode.
Manual Wakeup the Sensor
You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time.
Factory reset Door Sensor
Restore the Sensor (Door/Window detector) to Factory Default Settings
Reset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings.
1.Remove the device cover.
2.Make sure the sensor is powered.
3.Press and hold the button for 10 seconds,
4.Release the button.
Advanced Configuration
1. Configuring the OFF Delay
This configuration parameter that can be used to adjust the amount of delay before the OFF command is transmitted. This parameter can be configured with the value of 0 through 65535, where 0 means send OFF command immediately and 65535 means 65535 seconds of delay.
Function: On/Off Duration.
Parameter Number: 1.
Parameter Size: 2 Byte
Available Settings: 0 ~ 65535 (in seconds, each 1s).
Default Setting: 0 (s)
2. Basic Set Level
Basic Set Command will be sent where contains a value when the door/window is opened or closed, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set Command of which value is decisive as to how bright of dim level of lamp module shall be.
Function: Basic Set
Parameter Number: 2
Parameter Size: 1 Byte
Available Settings: 0, 1 ~ 99 or 255
0 – OFF, Alarm cancelling or turning a device off
1 ~ 99 or 255 – ON (Binary Switch Device) Dim Level (Multilevel Switch Device)
Default Setting: 255
Please note that this is a user manual Door Sensor from Coolcam is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Door Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.