The following is an overview of the user manual for the Z-Wave product Siren (NAS-AB02ZE)from Coolcam. To view other Z-Wave products and manuals from Coolcam follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Siren
SKU Code
NAS-AB02ZE
Description
This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Version #
HW: 96 FW: 2.17 was the version certified
Certification #
ZC10-18096227
Certified
2018-09-05T00:43:55.313327
Z-Wave Version
6.81.01

Security

As a Z-Wave Plus certified product, Siren supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Coolcam describes Siren as having the following features:

  • Battery Quantity
  • Communications Connections
  • Gateway Has Preferred Partners
  • Sensors
  • Supported Notification Types
  • Battery powered using CR123A batteries
  • Color
  • Firmware updatable via a compatible Z-Wave gateway
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Product Test Mode
1、 Press and hold the button.
2、 Power on the device, device will enter factory product test mode

1、 Power up the device.
2、 Set Z-Wave™ Controller into inclusion mode
3、 Press the button 3 times within 1.5s to enter inclusion mode.
4、 The device will be recognized and
automatically included into Z-Wave™ Network.

1、 Power up the device.
2、 Set Z-Wave™ Controller into exclusion mode
3、 Press the button 3 times within 1.5s to enter exclusion mode

Factory reset Siren

1、 Power up the device.
2、 Press and hold the button for 10s until led lights is on, then release the button.
Please use this procedure only when the network primary controller is missing or otherwise inoperable

The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then
2nd Smart Start time delay approximately 16s
3rd Smart Start time delay approximately 32s
4th Smart Start time delay approximately 64s
5th Smart Start time delay approximately 128s
6th Smart Start time delay approximately 256s
7th Smart Start time delay approximately 512s
Afterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down.

Please note that this is a user manual Siren from Coolcam is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Siren and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.