The following is an overview of the user manual for the Z-Wave product Water Sensor (NAS-WS01Z)from Coolcam. To view other Z-Wave products and manuals from Coolcam follow that link.
Overview
When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has been added a Z-Wave network. Please get familiar with the terms below before starting the operations.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Security
As a Z-Wave Plus certified product, Water Sensor supports Z-Wave S2 security. The following security modes are directly supported:
Features
Coolcam describes Water Sensor as having the following features:
- Sensors
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
Add the Sensor to Z-Wave Network
1.Remove the sensor cover.
2.Make sure the sensor is powered.
3.Set Z-Wave controller or Z-Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Delete the Sensor from Z-Wave Network
1.Remove the device cover.
2.Make sure the sensor is powered.
3.Set Z-Wave controller or Z-Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
4.Press the button three times within 1.5 second, the device will enter exclusion mode.
Factory reset Water Sensor
Restore the Sensor to Factory Default Settings
Note: to use the reset procedure only when the primary controller is missing or inoperable
Reset procedure will delete all information on the Z-Wave network and Z-Wave controller or Z-Wave Gateway, and restore the sensor to factory default settings.
1.Remove the device cover.
2.Make sure the sensor is powered.
3.Press and hold the button for 10 seconds, led will blink once.
4.Release the button.
Wakeup the Sensor Manual
User can press button once to wake-up this sensor to send wakeup notification to controller, the Led will be blink one time.
Please note that this is a user manual Water Sensor from Coolcam is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Water Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.