The following is an overview of the user manual for the Z-Wave product 738Zplus (738Zplus)from DMP. To view other Z-Wave products and manuals from DMP follow that link.
Overview
The 738Zplus is automatically recognized by DMP panels, and no additional programming is required.
Once the 738Zplus is connected to a DMP panel, users can immediately
begin adding Z-Wave devices to their system. Devices can be remotely controlled from smart phones using the DMP Virtual Keypad™ app.
Security
As a Z-Wave Plus certified product, 738Zplus supports Z-Wave S2 security. The following security modes are directly supported:
Features
DMP describes 738Zplus as having the following features:
- Communications Connections
- Color
- Door Lock Type
- Sensors
- Supported Notification Types
- Switch Type
- Thermostat Modes
- Thermostat HVAC Systems Supported
- Supported Meter Type
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
Note: To add the 738Zplus to an existing network, use the LRN (Learn) function.
1. Press CMD until MENU? YES NO appears, then press YES.
2. After accessing the User Menu, press CMD until ZWAVE SETUP? appears. Press any select key/area.
Factory reset 738Zplus
The 738Zplus can perform a Factory Default Reset by initializing defaults in the panel programming menu. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
REMOVE OR REPLACE DEVICES
If a device fails, users can remove or replace the device through the User Menu.
1. Press CMD until MENU? YES NO appears, then press YES.
2. After accessing the User Menu, press CMD until ZWAVE SETUP? appears. Press any select key/area.
3. Select LIST and press CMD until the device you are removing or replacing displays. Then, press any
select key/area to select the device.
4. Select STATUS. The status of the device displays as either OKAY or FAILED. If the device fails,
REMOVE FAILED DEVICE displays.
5. Select YES to remove the device. Press the second select key/area to replace the device.
6. If you chose to replace the device, PROCESSING displays.
7. When prompted, press the button (or series of buttons if adding a thermostat) on the replacement
device.
8. The keypad displays that the device has connected to your system.
Note: The replacement device keeps the orinigal device’s name.
ADD DEVICES
After wiring the 738Zplus to the panel, use a DMP keypad to program Z-Wave Plus devices into the panel
through the User Menu Z-Wave Setup option. This allows users to add devices through the User Menu
or the Virtual Keypad™ App after installation. When possible, have the Z-Wave device near the 738Zplus
during setup and programming.
When programming Z-Wave devices into an XT30, XT50, or XTLplus panel with Version 171 or higher, you
can add multiple devices at once. If you add multiple devices at once, then you will name each device after
they have all been added.
Note: To add the 738Zplus to an existing network, use the LRN (Learn) function.
1. Press CMD until MENU? YES NO appears, then press YES.
2. After accessing the User Menu, press CMD until ZWAVE SETUP? appears. Press any select key/area.
3. Select ADD. The screen displays PROCESSING.
4. When prompted, press the button (or series of buttons if adding a thermostat) on the device you
are adding.
5. The keypad displays that the device has connected to your system.
Please note that this is a user manual 738Zplus from DMP is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 738Zplus and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.