Flush Shutter DC (D-Shu-M-DC) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Flush Shutter DC (D-Shu-M-DC)from Dvaco. To view other Z-Wave products and manuals from Dvaco follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Flush Shutter DC
SKU Code
D-Shu-M-DC
Description
The Flush Shutter DC is ideal for controlling the 12–24V DC motors of blinds, rollers, shades, venetian blinds and similar sunscreens. You can control it either remotely through the Z-Wave network or through wall switches. It also measures power consumption and supports the connection of a digital temperature sensor.
Version #
HW: 1 FW: 6.04:06.05 was the version certified
Certification #
ZC10-18056121
Certified
2017-08-21T03:20:36.275495
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Flush Shutter DC supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Dvaco describes Flush Shutter DC as having the following features:

    • Supported Meter Type
    • Supported Notification Types
    • Window Covering Control Features
    • Sensors
    • Color
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    • Connect module to power supply
    • bring module within maximum 1 meter (3 feet) of the main controller,
    • enable add/remove mode on main controller,
    • press service button S for more than 6 second or
    • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.
    By this function all parameters of the module are set to default values and own ID is deleted.
    If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values.

    NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion.

    NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    • Connect module to power supply (with
    temperature sensor connected - if purchased),
    • auto-inclusion (works for about 5 seconds after connected to power supply) or
    • press service button S for more than 2 second or
    • press push button I1 three times within 3s (3 times change switch state within 3 seconds).

    NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

    NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.

    Factory reset Flush Shutter DC

    press service button S for more than 6 second or
    • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.
    By this function all parameters of the module are set to default values and own ID is deleted.
    If service button S is pressed more than 2 and less than 6 seconds (or if push button I1 is pressed three times within 3s) module is excluded, but configuration parameters are not set to default values.

    NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    Please note that this is a user manual Flush Shutter DC from Dvaco is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Flush Shutter DC and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.