Overview

Name
Door/Window Sensor
SKU Code
ZW1201
Description
This sensor monitors door/window and send Z-Wave™ signal when door or window is opened and closed.
Version #
HW: 1 FW: 20.15 was the version certified
Certification #
ZC10-17065648
Certified
2017-06-07T22:33:05.905364
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Door/Window Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Eva Logik describes Door/Window Sensor as having the following features:

    • Battery powered using CR14250 batteries
    • Color
    • Firmware updatable via a compatible Z-Wave gateway
    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Door/Window Sensor

    1. Press and hold the micro switch for at least 3 seconds while you insert the battery.
    2. Use this procedure only in the event that the network primary controller is missing
    or otherwise inoperable.

    The sensor was wake up when micro switch or magnetic sensor detect position changed after mounted on site.

    1. Follow the instructions for your Z-Wave certified controller to include a device to
    the Z-Wave network.
    2. Once the controller is ready to include your device, triple click the micro switch
    to include it in the network.
    3. Once your controller has confirmed that the device has been included, refresh the
    Z-Wave network to optimize performance.
    4. The device is associated in the same group when it included in setting process.
    Now you can control your Z-Wave device according to groups, scenes, schedules
    and automation programmed.

    1. Follow the instructions for your Z-Wave certified controller to exclude a device
    from the Z-Wave network.
    2. Once the controller is ready to Exclude your device, triple click the micro switch
    to exclude it from the network.

    Please note that this is a user manual Door/Window Sensor from EVA LOGIK is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Door/Window Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.