Smart Implant (FGBS-222) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Smart Implant (FGBS-222)from FIBARO. To view other Z-Wave products and manuals from Fibaro follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Smart Implant
SKU Code
FGBS-222
Description
FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication.
You can connect binary sensors, analog sensors, DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z-Wave controller.
It can also control devices by opening/closing output contacts independently of the inputs.

Main features of FIBARO Smart Implant:
- Compatible with any Z-Wave or Z-Wave Plus Controller,
- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption,
- Allows for connecting sensors:
o 6 DS18B20 sensors,
o 1 DHT sensor,
o 2 2-wire analog sensor,
o 2 3-wire analog sensor,
o 2 binary sensors.
- Works as a Z-Wave signal repeater,
- Built-in temperature sensor.
Version #
HW: 2 FW: 5.01 was the version certified
Certification #
ZC10-20036872
Certified
2020-03-03T17:32:43.7381
Z-Wave Version
6.81.01

Security

As a Z-Wave Plus certified product, Smart Implant supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Fibaro describes Smart Implant as having the following features:

  • Sensors
  • Supported Notification Types
  • Color
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

FIBARO Smart Implant is powered using DC power supply unit so it is always awake.

To remove the device from the Z-Wave network:
1. Power the device.
2. Set the main controller into remove mode (see the controller’s manual).
3. Quickly, triple click button on the device housing or switch connected to IN1 or IN2.
4. LED will start blinking yellow, wait for the removing process to end.
5. Successful removing will be confirmed by the Z-Wave controller’s message.

SmartStart location

SmartStart QR code's location as follows: page 15 chapter 5.2

Scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box).

Factory reset Smart Implant

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user configuration will be deleted.

Resetting the device is not the recommended way of
removing the device from the Z-Wave network. Use this procedure only when the network primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described.

1. Press and hold the button to enter the menu.
2. Release button when the device glows yellow.
3. Quickly click the button to confirm.
4. After few seconds the device will be restarted, which is signalled with the red colour.


To add the device to the Z-Wave network manually:
1. Power the device.
2. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
3. Quickly, triple click button on the device housing or switch connected to IN1 or IN2.
4. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box).
5. LED will start blinking yellow, wait for the adding process to end.
6. Successful adding will be confirmed by the Z-Wave controller’s message.

To add the device to the Z-Wave network using Smart Start:
1. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual).
2. Scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box).
3. Power the device.
4. LED will start blinking yellow, wait for the adding process to end.
5. Successful adding will be confirmed by the Z-Wave controller’s message.

Please note that this is a user manual Smart Implant from FIBARO is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Smart Implant and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.