The following is an overview of the user manual for the Z-Wave product A200-ch (GDM-M2D6D-K0)from GATEMAN. To view other Z-Wave products and manuals from GATEMAN follow that link.
Overview
'A200-CH' is a security enabled Z-Wave Plus product for Korean domestic market. It can be included and operated in any Z-Wave network with other Z-Wave certified devices.
Security
As a Z-Wave Plus certified product, A200-ch supports Z-Wave S2 security. The following security modes are directly supported:
Features
GATEMAN describes A200-ch as having the following features:
- Battery Quantity
- Battery powered using Alkline AA size batteries
- Color
- Door Lock Type
- Firmware updatable via a compatible Z-Wave gateway
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
To exclude:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,3,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button [Registration]
To include:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,1,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button [Registration]
The lock is always in 'Wake up status'.
However, touch with palm to begin and end action.
Factory reset A200-ch
To reset to factory defaults:
※ Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. (User code or master code remains the same. Only network settings reset to factory defaults.)
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,9,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button [Registration]
Please note that this is a user manual A200-ch from GATEMAN is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have A200-ch and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.