R200-ch (R200-CH) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product R200-ch (R200-CH)from GATEMAN. To view other Z-Wave products and manuals from GATEMAN follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
R200-CH
SKU Code
R200-CH
Description
Digital Doorlock by Gateman
Manufacturer: iRevo, ASSA ABLOY

Basic Feature:
- Usual doorlock features as locking and opening digitally

Remote Feature:
- RF connection by remote controller(certified by iRevo)
- Z-Wave connection with major telcomm platform providers(LGU+)
- Bluetooth connection with Gateman Smart Living service

Other detail functions can be found in Gateman website
- www.egateman.co.kr
Version #
HW: 32 FW: 32.16:16.16 was the version certified
Certification #
ZC10-17085751
Certified
2017-08-25T21:27:12.45315
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, R200-ch supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Access Control

Features

GATEMAN describes R200-ch as having the following features:

  • Color
  • Battery Quantity
  • Communications Connections
  • Door Lock Type
  • Gateway Has Preferred Partners
  • Battery powered using AA batteries
  • Supported Notification Types
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

To exclude:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,3,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button

To include:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,1,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button

Factory reset R200-ch

To reset to factory defaults:
※ Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. (User code or master code remains the same. Only network settings reset to factory defaults.)
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,9,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button

The lock is always in 'Wake up status'.
However, touch with palm to begin and end action.

Please note that this is a user manual R200-ch from GATEMAN is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have R200-ch and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.