Overview
Manufacturer: iRevo, ASSA ABLOY
Basic Feature:
- Usual doorlock features as locking and opening digitally
Remote Feature:
- RF connection by remote controller(certified by iRevo)
- Z-Wave connection with major telcomm platform providers(LGU+)
- Bluetooth connection with Gateman Smart Living service
Other detail functions can be found in Gateman website
- www.egateman.co.kr
Security
As a Z-Wave Plus certified product, R200-ch supports Z-Wave S2 security. The following security modes are directly supported:
- S2 Access Control
Features
GATEMAN describes R200-ch as having the following features:
- Color
- Battery Quantity
- Communications Connections
- Door Lock Type
- Gateway Has Preferred Partners
- Battery powered using AA batteries
- Supported Notification Types
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
To exclude:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,3,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button
To include:
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,1,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button
Factory reset R200-ch
To reset to factory defaults:
※ Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. (User code or master code remains the same. Only network settings reset to factory defaults.)
1. Touch keypad with palm
2. Enter User code(Normal Mode only. Enter Master code if operating Master Mode.)
3. Press 'R' button [Registration] from the inside of battery cover.
4. Press 9,#,9,# on the keypad (by sequence)
5. Wait until 'Ding dong dang' melody play than press 'R' button
The lock is always in 'Wake up status'.
However, touch with palm to begin and end action.
Please note that this is a user manual R200-ch from GATEMAN is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have R200-ch and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.