Z-trm3 (Z-TRM3) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Z-trm3 (Z-TRM3)from Heatit controls. To view other Z-Wave products and manuals from Heatit follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Heatit Z-TRM3
SKU Code
Z-TRM3
Description
Heatit Z-TRM3 is an electronic thermostat for electrical floor
heating, designed to be mounted in a standard flush box. The
thermostat has a built-in Z-Wave chip that can be connected with
Home Automation systems. Heatit Z-TRM3 has SmartStart. This
feature allows the user to include all devices with SmartStart by
scanning the QR codes on the devices. On startup all the devices
will automatically be included in the gateway (requires SmartStart
compability). This saves the installer a lot of work.

Heatit Z-TRM3 is equipped with a single pole switch and fits into
System 55 frames. The thermostat can withstand a load of max
16A /3600W at 230V. At higher loads the thermostat must control
a contactor. The thermostat may be connected to two wired
external sensors. The thermostat has the capacity of up to 5
associations (relays, wall plugs etc.).

The thermostat is designed for electrical heating. It may be
used for waterbased heating if the thermostat is linked with the
Heatit Z-Water.
Version #
HW: 3 FW: 4.00:04.00 was the version certified
Certification #
ZC10-20036889
Certified
2020-03-16T18:09:15.343262
Z-Wave Version
6.81.06

Security

As a Z-Wave Plus certified product, Z-trm3 supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Heatit describes Z-trm3 as having the following features:

  • IP (Ingress Protection) Rated
  • Switch Type
  • Thermostat HVAC Systems Supported
  • Thermostat Modes
  • Thermostat Power Source
  • Color
  • Neutral Wire Required
  • Firmware updatable via a compatible Z-Wave gateway
  • Switch Load Capacity Current
  • Switch Load Capacity Volt-Ampere
  • Switch Load Capacity Watts
  • Electric Load Type
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: The Z-Wave DSK can be found in the QR-Code and is located in 3 locations;
1. On the product box.
2. On the physical product, placed on the black plastic underneath the front.
3. On the PCB internally.

Remove.
The primary controller/gateway has a mode for removing devices. Please refer to your primary controller manual on how to set the primary controller in remove mode. The device may only be removed from the network if the primary controller is in remove mode. When the device is removed from the network, it will NOT revert to factory settings.

Removing mode is indicated on the display by rotating LED segments on the display. This lasts until the timeout occurs after 90 seconds, or until the module has been added/removed in the network. Confirmation will show Inc/EcL on the display. Exit programming mode by choosing ESC in the menu. Your thermostat is
now ready for use with default settings.
NB! When the thermostat is removed from the gateway, the parameters are not reset.

Chapter 8. Principles of regulation
Chapter 11. Standby and main screen
Chapter 12. Choice of sensor
Chapter 13. Selecting the right value for your external floor sensor
Chapter 14. Calibration
Chapter 17. Min/Max temperature settings
Chapter 18.1 Display on/off
Chapter 18.2 Childlock

Factory reset Z-trm3

By pressing buttons Right and Center (down and confirm) for 20 seconds, the thermostat will perform a complete factory reset.

NB! Please use this procedure only when the primary controller/gateway is missing or otherwise inoperable.
The device will display rES for 10 seconds while performing a factory reset. When rES no longer is displayed, the thermostat has been reset.

Add.
The primary controller/gateway has a mode for adding devices. Please refer to your primary controller manual on how to set the primary controller in add mode. The device may only be added from the network if the primary controller is in add mode.

There are two ways to add the Heatit Z-TRM3 to a Z-Wave network.

METHOD 1: STANDARD (MANUAL)
1. Press Center (confirm) for 10 seconds. The display will show OFF.
2. Press Right (down) 5 times until you see Con on the display.
3. Start the add/remove device process in your primary controller.
4. Start the add/remove mode in the Heatit Z-TRM3 by pressing Center (confirm) for approximately 2 seconds.

Adding mode is indicated on the display by rotating LED segments on the display. This lasts until the timeout occurs after 90 seconds, or until the module has been added in the network. Confirmation will show Inc/EcL on the display. Exit programming mode by choosing ESC in the menu. Your thermostat is now ready for use with default settings.

METHOD 2: SMARTSTART (AUTOMATIC)
SmartStart enabled products can be added into a Z-Wave network by scanning the Z-Wave QR-Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

Please note that this is a user manual Z-trm3 from Heatit controls is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-trm3 and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.