Z-Water (Z-Water) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Z-Water (Z-Water)from Heatit controls. To view other Z-Wave products and manuals from Heatit follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Heatit Z-Water
SKU Code
Z-Water
Description
Heatit Z-Water is equipped with 10 relay outputs and 4 analog inputs, and a Z-Wave radio for interfacing to the wireless
Z-Wave network.
The regulator can be power supplied from a 230V AC mains connection, and is able to deliver an output supply of 24V DC.
Heatit Z-Water relay outputs are able to be freely controlled from the Z-Wave network, and can be used for several
purposes, e.g. on/off control of light, control of valve actuators for an underfloor heating system, or control of other home
automation systems.
Heatit Z-Water inputs are analog inputs for interfacing simple temperature sensors; NTC, PT1000, etc.
It is possible to configure the level and the indication of the status indicator LED in the front of the Heatit Z-Water
regulator.
Version #
HW: 2 FW: 2.01 was the version certified
Certification #
ZC10-19036400
Certified
2019-03-16T01:10:07.879384
Z-Wave Version
6.71.03

Security

As a Z-Wave Plus certified product, Z-Water supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Heatit describes Z-Water as having the following features:

    • Switch Load Capacity Watts
    • Switch Load Capacity Current
    • Switch Load Capacity Volt-Ampere
    • Loads Controlled
    • Firmware updatable via a compatible Z-Wave gateway
    • Supported Notification Types
    • Electric Load Type
    • Sensors
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Z-Water

    Heatit Z-Water can be factory reset by pressing the small button through the little hole, marked with the text “INCLUSION”,
    in front of the Heatit Z-Water regulator for at least 10 seconds.

    NOTE: Only use this procedure when the primary network controller is missing or is otherwise inoperable.

    Add
    Please refer to your primary controller manual on how to enter
    add mode. The device can only be added from the network if the primary controller is in add mode.

    When the primary controller is set to add modus press
    the ”INCLUSION” button once on the device.

    Remove
    Please refer to your primary controller manual on how to enter
    remove mode. The device can only be removed from the network if the primary controller is in remove mode.

    When the primary controller is set to remove modus press
    the ”INCLUSION” button once on the device.

    Please note that this is a user manual Z-Water from Heatit controls is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-Water and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.