Overview

Name
Fan Coil Thermostat
SKU Code
HE-FT01
Description
The HE-FT01 is HELTUN’s advanced programmable Z-Wave thermostat for heating/cooling systems such as fan coil units, floor convectors, and wall, window, or ceiling mounted air conditioning units. The HE-FT01 thermostat is ‘impossibly thin’ on the wall while still being packed full of features, delivering highly accurate comfort control through proprietary technology and four built-in sensors.

You can monitor and control the HE-FT01 from anywhere in the world using a Z-Wave hub and your smartphone.* And because it uses Z-Wave Plus version 2, Smart Start, S2 Security and 700 platform technologies, the HE-FT01 can be placed up to 100 meters away from the hub and is a snap to install. Best of all, the built-in Power Consumption System precisely monitors how much energy you used during any particular day, week or month, helping you save money on energy costs while staying comfortable all year long.

The HELTUN HE-FT01 is part of an entire line of smart, connected products designed to provide the best technology has to offer without compromising stylish living.

(*hub and smartphone not included)
Version #
HW: 20 FW: 2.01 was the version certified
Certification #
ZC12-20010025
Certified
2019-12-12T18:44:56.068745
Z-Wave Version
7.11.1

Security

As a Z-Wave Plus certified product, Fan Coil Thermostat supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Heltun describes Fan Coil Thermostat as having the following features:

  • Firmware updatable via a compatible Z-Wave gateway
  • Thermostat HVAC Systems Supported
  • Thermostat Modes
  • Thermostat Power Source
  • Switch Type
  • Neutral Wire Required
  • Switch Load Capacity Current
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: The device DSK and QR code are printed on the HE-HF01 back panel plus on the manual included in the HE- FT01 packaging.

To remove HE-FT01 from a Z-Wave network (exclusion), do the following:
1. Enter “SETTINGS” Mode by pressing and holding the “Climate” button ( ) for three seconds.
2. Scroll menu to “Parameter 15 – nEt” using the “SPEED” button to scroll up, and the “MODE” button to scroll down.
3. The current state of the network will display in the Parameter Value position (bottom left corner). It should display “InC”. Note: If “EcL” is displayed, the HE-FT01 is already Excluded.
4. Start the Exclusion Mode from the gateway/controller.
5. Press the Minus “–” button in the HE-FT01 Parameter 15 to start the Exclusion process.
6. Note that lines will be moving in the Parameter value position (bottom left corner).
7. The Antenna icon should appear in the bottom right corner and “EcL” in the value position if the Exclusion was successful.
8. If the Antenna with signal strength bars icon or “InC” in value position are displayed, repeat the Exclusion process.
Note: If the HE-FT01 has previously been part of a Z-Wave network and has not been Excluded since, Inclusion is not possible without first performing an Exclusion or Factory Reset procedure.
Note: If the HE-FT01 is included in the Z-Wave network the antenna icon will appear in the bottom right corner of the main screen with signal strength bars.

Factory reset Fan Coil Thermostat

By pressing and holding the “MODE” button for 6 seconds, the HE-FT01 will enter Factory Reset Mode, displaying “REs” in the left bottom corner, “y” and “n” in the center. Press the Plus (+) button to revert to factory settings, or the “SPEED” button to cancel.
The factory reset will change all the Parameters to their original factory default values and will also Exclude the device from any Z-Wave network.
Please use Factory Reset only when the primary network controller is missing or otherwise inoperable.

To add HE-FT01 into a Z-Wave network (inclusion), do the following:
1. Enter “SETTINGS” Mode by pressing and holding the “Climate” button for three seconds.
2. Scroll menu to “Parameter 15 – nEt” using the “SPEED” button to scroll up, and the “MODE” button to scroll down.
3. The current state of the network will display in the Parameter Value position (bottom left corner). It should display “EcL”. Note: If “InC” is displayed, the HE-FT01 must first be Excluded from an existing Z-Wave network (see “Removal from a Z-Wave Network” below).
4. Start the Inclusion Mode from the gateway/controller.
5. On the HE-FT01 in Parameter 15, press the Plus “+” key to start the Inclusion process.
6. Note that lines will be moving in the Parameter value position (bottom left corner).
7. The Antenna with signal strength bars icon should appear at the bottom right corner if Inclusion was successful.
8. If the Antenna icon without bars is displayed or “Err” is in the Value position, the HE-FT01 Inclusion was not successful (try repeating steps 4-7).

Please note that this is a user manual Fan Coil Thermostat from HELTUN is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Fan Coil Thermostat and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.