Overview

Name
Z-Wave Rotary Dimmer Switch
SKU Code
EU-P10
Description
The Dimmer controller is a switch multilevel device based on Z-Wave and it can be easy configuration, operation and can make the traditional LED dimmable lighting to be intelligent control. This Dimmer integrated Z-Wave communication module to connect with Z-Wave gateway and this device can be adapted to EU (868.42Mhz)
The Dimmer controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
The Dimmer controller is also a security Z-Wave device and supports the Over The Air (OTA) feature for the product’s firmware upgrade.
If you want your Dimmer controller to be a security device that use secure/encrypted message to communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.
Version #
HW: 1 FW: 1.17 was the version certified
Certification #
ZC10-20036888
Certified
2020-03-13T10:31:20.343163
Z-Wave Version
6.81.03

Security

As a Z-Wave Plus certified product, Z-Wave Rotary Dimmer Switch supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Hzc Electric describes Z-Wave Rotary Dimmer Switch as having the following features:

  • Switch Type
  • Communications Protocol
  • Firmware updatable via a compatible Z-Wave gateway
  • Switch Load Capacity Watts
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

1. Set primary controller/gateway into exclusion mode (If you don’t know how to do this, please refer to your primary controller’s manual on how to turn your controller into exclusion mode).
2. Short press 2 times the reset button, it will set the dimmer controller into exclusion mode (The dimmer controller already exists a Z-Wave network). 25 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
3. The dimmer controller will be removed from the Z-Wave network.

Note:
The Dimmer will start SmartStart Inclusion when it is removed from a Z-wave network.

1. Set primary controller/gateway into exclusion mode (If you don’t know how to do this, Please refer to your
primary controller’s manual on how to turn your controller into exclusion mode).
2. Power on the dimmer controller again, it will set the dimmer controller into exclusion mode (The dimmer
controller already exists a Z-Wave network). 25 seconds timeout if there is no reply from the Z-Wave primary
controller, repeat the operation.
3. The dimmer controller will be removed from the Z-Wave network.

1. Power on the dimmer controller, press and hold down the reset button for over 4 seconds, it will set the dimmer
controller into inclusion mode.25 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
2. The dimmer controller will be added to the Z-Wave network.

Factory reset Z-Wave Rotary Dimmer Switch

Press and hold down reset button for over 4 seconds, the dimmer controller will be reset to factory defaults.

Note:
This procedure should only be used when the primary controller is inoperable.

Reset Dimmer controller to factory default settings will sets the Dimmer to not in z-wave network state, delete the Association setting and restore the Configuration setting to the default.
The Dimmer controller will start SmartStart Inclusion when it is reset.

1. Set primary controller/gateway into inclusion mode (If you don’t know how to do this, please refer to your primary controller’s manual on how to turn your controller into inclusion mode).
2. Short press 2 times the reset button, it will set the dimmer controller into inclusion mode.25 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
3. The dimmer controller will be added to the Z-Wave network.

SmartStart location

SmartStart QR code's location as follows: You scan the QR code with an android phone. For example, the QR Code may be scanned by the application provided with your SmartStart compatible Z-Wave controller. ( The data for each Dimmer is different)


Note: If your controller does not support SmartStart inclusion, please refer to the manual for your controller for non-SmartStart inclusion.

1. Set primary controller/gateway into inclusion mode (If you don’t know how to do this, Please refer to your
primary controller’s manual on how to turn your controller into inclusion mode).
2. Power on the dimmer controller, press and hold down the reset button for over 4 seconds, it will set the dimmer
controller into inclusion mode.25 seconds timeout if there is no reply from the Z-Wave primary controller, repeat
the operation.
3. The dimmer controller will be added to the Z-Wave network.

Please note that this is a user manual Z-Wave Rotary Dimmer Switch from HZC ELECTRIC is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-Wave Rotary Dimmer Switch and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.