The following is an overview of the user manual for the Z-Wave product 150 Z-Wave module (ID-150)from ID Lock. To view other Z-Wave products and manuals from ID Lock follow that link.
Overview
The module is compatible with ID Lock 150.
It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications.
Security
As a Z-Wave Plus certified product, 150 Z-Wave module supports Z-Wave S2 security. The following security modes are directly supported:
Features
ID Lock describes 150 Z-Wave module as having the following features:
- Door Lock Type
- Firmware updatable via a compatible Z-Wave gateway
- Supported Notification Types
- Battery Quantity
- Battery powered using AA batteries
- Color
- IP (Ingress Protection) Rated
- Outdoor Use
- Sensors
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
Factory reset 150 Z-Wave module
Device reset – (This will reset RF interface module to factory default settings)
Warning: Please do only proceed with the following reset procedure, if primary network controller is missing or otherwise inoperable.
Warning: If device reset is performed when connected to a controller the door lock will factory reset.
RESET Z-WAVE MODULE:
• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state).
• Release button.
• Enter Master PIN followed by * on keypad.
• Press digit ""2"" for settings followed by * on keypad.
• Press digit “0” on keypad.
If the Z-wave module is not included in a Z-wave network the door lock will also return to factory settings when following the above procedure.
FACTORY RESET DOOR LOCK FIRMWARE:
• Push and hold inside lock/unlock button while inserting the fourth battery.
• Receive reset sound.
• Release button.
• Receive confirmation sound.
Exclusion – (Puts your device in exclusion mode)
• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state).
• Release button.
• Enter Master PIN followed by * on touch panel.
• Press digit ""2"" for settings followed by * on touch panel.
• Press digit “5” on touch panel.
Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue.
Inclusion – (Puts your device in inclusion mode)
• Push and hold key button until all LEDs on touch panel activates (with ID Lock in an unlocked state).
• Release button.
• Enter Master PIN followed by * on touch panel.
• Press digit ""2"" for settings followed by * on touch panel.
• Press digit “5” on touch panel.
Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue.
Activate by touching the touch panel with multiple fingers or the palm of the hand on the outside unit or by pushing the key button on the inside unit.
Wakeup is not recommended by touching the * or # symbol on the touch panel.
Notification parameter in COMMAND_CLASS_NOTIFICATION_V4
Events:
- Manual Unlock Operation
- Manual Lock Operation
- PIN Unlock Operation
- RFID Unlock Operation
- Z-wave unlock
- Z-wave lock
- Unlock Request by Unknown PIN
- Unlock Request by Unknown RFID
- Locked by autolock
- Lock jammed
Events:
- Forced Open Alarm triggered
- Forced Open Alarm Idle
- High temperature Alarm Triggered
- High temperature Alarm Idle
Please note that this is a user manual 150 Z-Wave module from ID Lock is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 150 Z-Wave module and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.