  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
3CH Touch Wall Switch
SKU Code
JTB-3011-03
Description
The product is designed to operate with neutral wire control three channel loads individually. Zero-cross detect function to support a large load of less than 800 Watt per channel.

Each channel supports associated control another multi-channel endpoint to setup multi-control switch.

An individual led indicates inclusion/exclusion processing status.

Standard 86 size box with 25mm depth of embedded only.
Version #
HW: 33 FW: 1.01 was the version certified
Certification #
ZC10-17115828
Certified
2017-10-31T20:33:01.375699
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, 3CH Touch Wall Switch supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Jintaobao describes 3CH Touch Wall Switch as having the following features:

    • Switch Load Capacity Current
    • Electric Load Type
    • Switch Load Capacity Volt-Ampere
    • Switch Load Capacity Watts
    • Loads Controlled
    • Neutral Wire Required
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Association Group 2,4,6 is assigned to send Basic Set On frame to associated devices corresponding while channel 1,2,3 switch turn on, it can easily setup multi-control another switch turn on together.

    Meanwhile, association Group 3,4,7 is assigned to send Basic Set Off frame to associated devices corresponding while channel 1,2,3 switch turn off.

    Start master controller add device mode as instruction, press and hold the channel 1 touch icon (located on leftmost) for 2 second, RF icon LED on right bottom flash
    indicator inclusion processing until included or 60 seconds timeout no detect any master controller.

    Start master controller remove device mode as instruction, press and hold the channel 1 touch icon (located on leftmost) for 2 second, RF icon LED on right bottom flash indicator inclusion processing until included or 15 seconds timeout no detect any master controller.
    LED flash slowly indicated has no included any controller.

    Factory reset 3CH Touch Wall Switch

    The factory default settings are restored when the device is removed from the network.
    Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    Please note that this is a user manual 3CH Touch Wall Switch from Jintaobao is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 3CH Touch Wall Switch and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.