PIR-Z-Wave (IX32-Z-Wave) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product PIR-Z-Wave (IX32-Z-Wave)from KPL. To view other Z-Wave products and manuals from KPL follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
PIR-Z-Wave
SKU Code
IX32-Z-Wave
Description
The Z-Wave sensor is equipped with Z-Wave500 series main control chip. It is a passive infrared intrusion sensor that adopts Energy Integration Logical Processing, Random Dynamic Time Segmentation & Digital Signal Processing Technologies. With precise columnar Fresnel lens, it can increase its energy receiving efficiency and sensitivity without false alarm. In conjunction with advanced software technology, it will make an accurate judgement between real intruder & interference factors that may cause false alarm. Superior ability to detect & prevent false positives. The pulse number is optional, suitable for kinds of residential constructions, preventing false positive & false negative that other ordinary indoor sensors cannot do. Its performance is far beyond other ordinary PIR alarms. Besides, we use large capacity built-in battery & special power saving solution, battery working life is up to 3 years.
Version #
HW: 255 FW: 5.36 was the version certified
Certification #
ZC10-19076690
Certified
2019-07-30T20:38:12.619929
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, PIR-Z-Wave supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    KPL describes PIR-Z-Wave as having the following features:

    • Sensors
    • Battery powered using AA batteries
    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.

    a) Manual Wake-up
    Quickly press tamper switch once, the PIR sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information.
    b) Automatic Wake-up
    Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min.

    enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will be removed after a period of time.

    Factory reset PIR-Z-Wave

    Press the anti-tamper switch for 6 times within 2.5 seconds to restore factory settings(Please include a request to use the reset procedure only when the primary controller is missing or inoperable).

    Please note that this is a user manual PIR-Z-Wave from KPL is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have PIR-Z-Wave and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.