  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
PIR-ZWAVE
SKU Code
IX30-ZWAVE
Description
IX30-Z-Wave is a digital micro-control intrusion detector adopting Energy Accumulation Logical Processing & Random Dynamic Time Segmentation Technology. With precise columnar Fresnel lens, IX30-Z-Wave can increase its energy receiving efficiency and sensitivity without false alarm. In conjunction with advanced software technology, it will make an accurate judgment between real intruder & interference factors that may cause false alarm. Superior ability to detect & prevent false positives.
Version #
HW: 255 FW: 5.36 was the version certified
Certification #
ZC10-17035481
Certified
2017-03-14T01:14:55.392329
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Pir-zwave supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    KPL describes Pir-zwave as having the following features:

    • Supported Notification Types
    • Battery Quantity
    • Battery powered using AA batteries
    • Sensors
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Pir-zwave

    Press the anti-tamper switch for 6 times within 2.5 seconds to restore factory settings(Please include a request to use the reset
    procedure only when the primary controller is missing or inoperable)

    a) Manual Wake-up Quickly press tamper switch once, the PIR sensor will automatically send wake-up information, and there will be 10s after wake-up to receive gateway setting information.
    b) Automatic Wake-up Default time of automatic wake-up is 24 hours, and there will be 10s after wake-up to receive gateway setting information, the max automatic report time = 24 hours, minimum=30min

    enter the Exclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will be removed after a period of time.

    enter the Inclusion Mode of gateway, and press the tamper switch 3 times within 1.5s, then the PIR sensor will stay in enrollment state until successfully enrolled into network or enrollment time out after 30s.

    Please note that this is a user manual Pir-zwave from KPL MOTION SENSOR is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Pir-zwave and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.