  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Door/Window Sensor
SKU Code
7A-SS-VE-H0
Description
The LEEDARSON Door/Window Sensor is a wireless sensor that is powered by a CR2 battery. The door/window sensor lets you know when a door or window is opened, or closed, and can trigger different actions in response to that open action or close action. This sensor uses the Z-Wave communication module to connect with Z-Wave Gateway. This device can be adapted to use in the EU(868.42Mhz) and US. The door/window sensor supports the Over The Air (OTA) feature for the product’s firmware upgrade. If you want your Door/Window Sensor to be a security device that uses secure/encrypted messages to communicate in a Z-Wave network, then a security enabled Z-Wave controller/gateway is needed.
Version #
HW: 32 FW: 1.08 was the version certified
Certification #
ZC10-18036058
Certified
2018-03-12T16:37:59.018669
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, Door/Window Sensor supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

Leedarson describes Door/Window Sensor as having the following features:

  • Battery Quantity
  • Battery powered using CR batteries
  • Firmware updatable via a compatible Z-Wave gateway
  • Sensors
  • Supported Notification Types
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Add for inclusion:
1). Insert the battery.
2). Set the Z-Wave network main controller into learning mode.
3). Triggering this action button.
4). If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step

Remove for exclusion;
1. Insert the CR battery.
2. Set the Z-Wave network main controller into exclusion mode.
3. Triggering this action button.
If the remove for exclusion is successful, the LED will blink fast and turn off. Otherwise, the LED will keep solid for 2 seconds and then turn off, in which case you need to repeat the process from step 2.

Factory reset Door/Window Sensor

LED will blink fast for 5 seconds and then keep solid for 3 seconds, after that Door/Window Sensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network.

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

1. Short press 3 time.
2. LED will blink one time; sending wake up notification cc

Please note that this is a user manual Door/Window Sensor from LEEDARSON is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Door/Window Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.