Open Sensor (osr-02) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Open Sensor (osr-02)from LG U+. To view other Z-Wave products and manuals from LG follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Open Sensor
SKU Code
osr-02
Description
Remote Access via smart phone APP
Detecting the status of Door/Windows equipped with Z-WAVE Open Sensor and notifying the status to a customer.
Checking the battery usage and reporting the low battery alarm.
Version #
HW: 1 FW: 39.16 was the version certified
Certification #
ZC12-19090010
Certified
2019-09-11T14:17:28.646357
Z-Wave Version
7.11.1

Security

As a Z-Wave Plus certified product, Open Sensor supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

LG describes Open Sensor as having the following features:

  • Battery powered using AAA batteries
  • Color
  • Battery Quantity
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: QR code and PIN code is located above the battery insertion position.
Please refer to Section 17 of the manual

a. Receiver will stay exclusion waiting mode.
b. Press & hold Inclusion/Exclusion button for 5 seconds when Door Sensor is Inclusion status.
c. LED of Door sensor will be on 5 seconds later.
d. Door sensor will try Exclusion when button is released.
e. LED will blink 3 times with 250ms interval if Exclusion is successful.

a. Device sends Wake up Notification by every 15 minutes(default).
b. Devices also sends Wake up Notification when inclusion/exclusion button is shortly pressed(200ms~1sec) regardless of 15minutes interval.

a. Press & hold Inclusion/Exclusion button for 5 seconds when Door Sensor is exclusion status.
b. LED of Door sensor will be on 5 seconds later.
c. Door sensor will try Inclusion for 30sec when button is released.
d. LED will blink 3 times with 250ms interval if Inclusion is successful.

Factory reset Open Sensor

a. Press & hold Inclusion/Exclusion button for 10sec.
b. LED will blink while holding the button.
c. Factory reset will be done in 5sec after releasing button and LED will blink 5 times with 100ms interval.
* Please use this procedure only when the network primary controller is missing or otherwise inoperable.

* Configuration Parameters
a. Parameter Number : Battery Period (0x01).
b. Description of parameter and its effect on the product : Battery Report Period Value
c. Default value : 0x18
d. Size (Number of bytes) : 1 Byte
e. Possible Values : 0x01 ~ 0xFF

Please note that this is a user manual Open Sensor from LG U+ is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Open Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.