Zoe Shutter H (HZ07100) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Zoe Shutter H (HZ07100)from Master. To view other Z-Wave products and manuals from Master follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
ZOE SHUTTER H
SKU Code
HZ07100
Description
ZoeShutter is a line-powered Z-Wave interface for 1 actuation (roller shutter) and 2 pushbuttons
(opening/closing). Compatible with any Vesta board HM02000+HA40000/HA40100/HA40200. Supports secure mode (Z-Wave network security mode) with AES-128 encryption. Advanced microprocessor control. Works with pushbuttons.
To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations.
ZoeShutter can work as stand-alone device, and can be connected to a Z-Wave network.
Version #
HW: 2 FW: 6.04:06.05 was the version certified
Certification #
ZC10-22017068
Certified
2022-01-04T15:06:18.477576
Z-Wave Version
6.51.09

Security

As a Z-Wave Plus certified product, Zoe Shutter H supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Master describes Zoe Shutter H as having the following features:

    • Color
    • Electric Load Type
    • Neutral Wire Required
    • Switch Load Capacity Current
    • Switch Load Capacity Watts
    • Window Covering Control Features
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Module Inclusion (Adding to Z-Wave network)
    • Connect module to power supply (with
    temperature sensor connected - if purchased),
    • auto-inclusion (works for about 5 seconds after connected to power supply) or
    • press push button I1 three times within 3s (6 times change switch state within 3 seconds) or
    • press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.
    NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
    NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.

    • Connect module to the power supply
    • bring module within a maximum 1 meter (3 feet) of the main controller,
    • enable add/remove mode on the main controller,
    • press push button I1 5 times within 3s (10 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
    • press service button S (only applicable for 24 V SELV supply voltage) for more than 6 seconds.
    By this function all parameters of the module are set to default values and their own ID is deleted.
    If push button I1 is pressed 3 times within 3s (6 times change switch state within 3 seconds) (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
    NOTE: If the module is included with parameters 71 with a value different to default and module reset is done, wait for at least 30s before the next inclusion
    FACTORY RESET
    1. Connect the device to the power supply
    2. Within the first minute the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds
    OR
    If the device is powered by 24 Vdc SELV supply, press and hold the S (Service) button for at least 6 seconds
    By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the gateway (hub) is missing or otherwise inoperable.
    NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable

    Factory reset Zoe Shutter H

    FACTORY RESET
    1. Connect the device to the power supply
    2. Within the first minute the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds
    OR
    If the device is powered by 24 Vdc SELV supply, press and hold the S (Service) button for at least 6 seconds
    By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted. Use this reset procedure only when the gateway (hub) is missing or otherwise inoperable.
    NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable

    Please note that this is a user manual Zoe Shutter H from Master is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Zoe Shutter H and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.