Heating Thermostat (MH7H-WH/EH) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Heating Thermostat (MH7H-WH/EH)from MCO Home. To view other Z-Wave products and manuals from MCO Home follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Heating Thermostat
SKU Code
MH7H-WH/EH
Description
MH7H-WH is mainly applied to control wall mounted boiler, water valve/pump etc. , while MH7H-EH is for electrical heating system.The device is of high reliability and practicability, which can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Features:
 Capacitive touch buttons
 Tempered glass panel, PC alloy enclosure
 Precise temperature calibration function
 Attractive appearance
 Clear display, easy to operate

Specification:
 Power Supply:AC85-260V, 50/60HZ
 Output: MH7H-WH ≤5A ; MH7H-EH≤ 16A
 Self Consumption:≤1W
 External Temp. Sensor(optional): NTC R25℃=15KΩ
B25℃/50℃=3550K
 Working Environment:0-50℃; 0-90% RH(Non-
condensation)
 Temperature Setting:5-37 ℃(41-99℉)(Adjustable)
 Dimension:86* 86*15mm
 Hole Pitch:60-61mm

Version #
HW: 255 FW: 3.01 was the version certified
Certification #
ZC10-18046084
Certified
2018-04-17T23:45:00.460457
Z-Wave Version
6.71.01

Security

As a Z-Wave Plus certified product, Heating Thermostat supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

MCO Home describes Heating Thermostat as having the following features:

  • Thermostat HVAC Systems Supported
  • Thermostat Modes
  • Thermostat Power Source
  • Firmware updatable via a compatible Z-Wave gateway
  • Switch Load Capacity Current
  • Neutral Wire Required
  • Sensors
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press S4 once, device will enter learning mode to get a node ID. If adding is succeed, a node ID will display on the screen in a few seconds.

A node ID can always inform us whether the device is in the network or not.

After adding, turn off the device and then turn it on. Now the device is ready to be operated by controller/ gateway in Z-Wave network.

In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device removed from network, a Node ID will display on the screen. Then press S4 once. If removing is succeed, “- - -”will display on the screen in a few seconds.

A node ID can always inform us whether the device is in the network or not.When removed, the device will restore its factory setting.

Factory reset Heating Thermostat

A parameter P18 in the secret menu can be used to restore factory setting locally. Please use this procedure only when the network primary controller is missing or otherwise inoperable. ; And a parameter FF can be used to restore the factory setting via Z-Wave.

Please note that this is a user manual Heating Thermostat from MCO Home is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Heating Thermostat and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.