Overview
Features:
Capacitive touch buttons
Tempered glass panel, PC alloy enclosure
Precise temperature calibration function
Attractive appearance
Clear display, easy to operate
Specification:
Power Supply:AC85-260V, 50/60HZ
Output: MH7H-WH ≤5A ; MH7H-EH≤ 16A
Self Consumption:≤1W
External Temp. Sensor(optional): NTC R25℃=15KΩ
B25℃/50℃=3550K
Working Environment:0-50℃; 0-90% RH(Non-
condensation)
Temperature Setting:5-37 ℃(41-99℉)(Adjustable)
Dimension:86* 86*15mm
Hole Pitch:60-61mm
Security
As a Z-Wave Plus certified product, Heating Thermostat supports Z-Wave S2 security. The following security modes are directly supported:
- S2 Unauthenticated
Features
MCO Home describes Heating Thermostat as having the following features:
- Thermostat HVAC Systems Supported
- Thermostat Modes
- Thermostat Power Source
- Firmware updatable via a compatible Z-Wave gateway
- Switch Load Capacity Current
- Neutral Wire Required
- Sensors
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press S4 once, device will enter learning mode to get a node ID. If adding is succeed, a node ID will display on the screen in a few seconds.
A node ID can always inform us whether the device is in the network or not.
After adding, turn off the device and then turn it on. Now the device is ready to be operated by controller/ gateway in Z-Wave network.
In normal working interface, press & hold S4 to enter interface for adding or removing of Z-Wave network. Before device removed from network, a Node ID will display on the screen. Then press S4 once. If removing is succeed, “- - -”will display on the screen in a few seconds.
A node ID can always inform us whether the device is in the network or not.When removed, the device will restore its factory setting.
Factory reset Heating Thermostat
A parameter P18 in the secret menu can be used to restore factory setting locally. Please use this procedure only when the network primary controller is missing or otherwise inoperable. ; And a parameter FF can be used to restore the factory setting via Z-Wave.
Please note that this is a user manual Heating Thermostat from MCO Home is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Heating Thermostat and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.