Overview

Name
Door Sensor
SKU Code
MC01-1702OPS
Description
MC01-1702OPS offers information whether a door is open or closed.

This is a battery-powered device, which is in sleeping mode unless an action is detected.
After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping mode.

Batteries can be changed with screwing the device from the frame.

The device needs to be included into a Z-Wave network by the Z-Wave controller.
Version #
HW: 1 FW: 1.01 was the version certified
Certification #
ZC10-17125911
Certified
2017-12-20T01:01:09.669448
Z-Wave Version
6.61.01

Security

As a Z-Wave Plus certified product, Door Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Mercury describes Door Sensor as having the following features:

    • Color
    • Firmware updatable via a compatible Z-Wave gateway
    • Sensors
    • Supported Notification Types
    • Battery powered using AAA type/1.5V batteries
    • Battery Quantity
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    1) Put the Z-Wave Controller into inclusion mode
    2) Press the Push button one time in door sensor

    1) Put the Z-Wave Controller into exclusion mode
    2) Press the Push button three times in door sensor

    Factory reset Door Sensor

    1) Press the Push button for more than 10 seconds
    2) Verify that LED is blinking one time
    ※ Please use this procedure only when the network primary controller is missing or otherwise inoperable

    There are 2 ways;
    When press the Push button two times
    when the door state changes, e.g,. Open or Close

    -Minimum Wake Up Interval : 0 seconds
    -Maximum Wake Up Interval : 4200 seconds(70 minutes)
    -Default Wake Up Interval : 4200 seconds(70 minutes)
    -Wake Up Interval Step Seconds : 10 seconds

    Please note that this is a user manual Door Sensor from Mercury is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Door Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.