Radio I/O Modul (MTIOM-100-WL) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Radio I/O Modul (MTIOM-100-WL)from myTEM SmartHome. To view other Z-Wave products and manuals from myTEM SmartHome follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Radio I/O Modul
SKU Code
MTIOM-100-WL
Description
The Radio IO Modul MTIOM-100-WL is a universal, Z-Wave compatible module from myTEM for extending your smart home system with additional inputs and outputs. It is a Z-Wave device of the type Binary Switch for the use in Europe / Switzerland.

Main use is for:
- Switching of lights
- Switching of single-phase fan motors
- Switching of electric blinds or similar shading devices
- Operation by means of buttons, sensors via the central server

Functions:
- Supply voltage 24 VDC ± 10%
- Communication via Z-Wave mesh network
- 6 digital inputs 24 VDC (DI1 – DI6) for e.g. external switches
- 24 VDC power supply, 100 mA, for the digital inputs DI1 – DI6 (VDIout)
- 4 analog inputs (AI1 – AI4), which can be used for 0-10 VDC or NTC-, PTC- or PT1000 sensors. Analog inputs can also be used as digital inputs 24 VDC.
- 6 digital outputs with potential-free, relay 8 A, 250 VAC
- Manual positions of the outputs via DIP switch for easy commissioning
- The device is installed in a control cabinet, mounted on a 35 mm DIN rail
Version #
HW: 0 FW: 1.00:00.07 was the version certified
Certification #
ZC12-21020178
Certified
2021-02-02T20:25:06.80291
Z-Wave Version
7.13.2

Security

As a Z-Wave Plus certified product, Radio I/O Modul supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated
  • S2 Unauthenticated

Features

myTEM SmartHome describes Radio I/O Modul as having the following features:

  • Electric Load Type
  • Loads Controlled
  • Z-Wave Scene Type
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Manual inclusion/exclusion (“Add/Remove”)

If the myTEM Radio IO Modul Floor shows status “Add”, the “Remove” can be performed with any controller in the network or with the help of a new controller. However, it is recommended to use the primary controller of the previous network unless it is no longer available or damaged.

“Remove” deletes the memory chip, including all Z-Wave network settings.

1. Activate the “Add” or “Remove” mode on your controller.
2. Press the button (T) four times in quick succession to start include / exclude (“Add / Remove”).

When the device is in the “Add” mode, the LED flashes green.
When finished, the new status is:
Add: The LED 2 lights up briefly in green
Remove: The LED 2 lights up briefly in red

Factory reset Radio I/O Modul

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Power-up the device and then press the button (T) for 10 seconds.

Reset: The LED lights up briefly in red

The device reset deletes the memory chip, including all Z-Wave network settings.

SmartStart location

SmartStart QR code's location as follows: The DSK label (QR code) is located on the long side of the housing.

Manual inclusion/exclusion (“Add/Remove”)

1. Activate the “Add” or “Remove” mode on your controller.
2. Press the button (T) four times in quick succession to start include / exclude (“Add / Remove”).

When the device is in the “Add” mode, the LED flashes green.
When finished, the new status is:
Add: The LED 2 lights up briefly in green
Remove: The LED 2 lights up briefly in red

Please note that this is a user manual Radio I/O Modul from myTEM SmartHome is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Radio I/O Modul and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.