4 kanaler bryter (4 kanaler bryter) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product 4 kanaler bryter (4 kanaler bryter)from Namron. To view other Z-Wave products and manuals from Namron follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
4 kanaler bryter
SKU Code
4 kanaler bryter
Description
The remote control is a Z-Wave device that can both control other Z-Wave devices and activate scenes in
Gateways. Although it is controlling other devices, the device cannot act as Z-Wave network controller (primary
or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. It also
supports the Over The Air (OTA) feature for the product’s firmware upgrade.
The remote control has following functions:
1. Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands.
2. Activation of scenes in Gateway mode.
The encryption modes that the remote control supports are S0, S2 Authenticated, S2 Unauthenticated. When
the remote control is being included into a Z-Wave network, you can use your primary controller/gateway to
enable one encryption mode or disable encryption. (The primary controller/gateway shall support encryption
mode configuration).
Version #
HW: 1 FW: 1.26 was the version certified
Certification #
ZC10-19096755
Certified
2019-09-17T13:17:04.174821
Z-Wave Version
6.71.03

Security

As a Z-Wave Plus certified product, 4 kanaler bryter supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Namron describes 4 kanaler bryter as having the following features:

  • Firmware updatable via a compatible Z-Wave gateway
  • Z-Wave Scene Type
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Factory reset 4 kanaler bryter

Press and hold down both buttons I and O of Group 2 for over 10 seconds, LED indicator turns on and then
blinks 4 times quickly to indicate successful factory reset.Please use this procedure only when the network
primary controller is missing or otherwise inoperable.

Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED indicator turns on, it means the remote control has already been included to a network, please first set the remote control to exclusion mode (refer to the part Exclusion"" of this manual),then continue step 2.
Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).
Step 3. Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 times
quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it will not enter into sleepy mode immediately, and will continue activation status for 30s and wait data interaction from the gateway, the LED indicator will stay solid on, please be patient to wait LED indicator to turn off.

There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
2. Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on, the remote control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion.

The remote control is under sleepy mode for most of the time to save battery power. It can not receive wireless
command under sleepy mode. Before the gateway interacts data with the remote, the remote control shall be
activated manually first. Short press any button to activate the remote control for 3s, and press and hold down
I and O buttons of Group 2 over 1 second to activate the remote control.

There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on
how to set your controller into exclusion).
2. Press and hold down both buttons and of Group 2 over 3 seconds, LED indicator turns on, the remote
control will be set to exclusion mode, and waiting to be excluded, after 7s LED indicator blinks 4 times quickly to indicate successful exclusion.
Method 2: Factory reset the remote control will force the remote control to be excluded from a network. (please refer to the part “Factory Reset” of this manual)

Step 1. Make sure the remote control does not belong to any Z-Wave network, short press any button, if LED
indicator does not turn on, the remote control does not belong to any network, then continue step 2,if LED
indicator turns on, it means the remote control has already been included to a network, please first set the
remote control to exclusion mode (refer to the part "Exclusion" of this manual),then continue step 2.
Step 2. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on
how to turn your controller into inclusion).
Step 3. Press and hold down both buttons I and O of Group 2 over 3 seconds, LED indicator turns on, the
remote control will be set to inclusion mode, and waiting to be included, after 10s LED indicator blinks 6 times
quickly to indicate successful inclusion. The remote control is a sleepy device, after inclusion it will not enter
into sleepy mode immediately, and will continue activation status for 30s and wait data interaction from the
gateway, the LED indicator will stay solid on, please be patient to wait LED indicator to turn off.

Please note that this is a user manual 4 kanaler bryter from Namron is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have 4 kanaler bryter and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.