Roll-Control (FGR-223) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Roll-Control (FGR-223)from Nice. To view other Z-Wave products and manuals from Nice follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Roll-Control
SKU Code
FGR-223
Description
FIBARO Roller Shutter 3 is a device designed to control roller blinds, awnings, venetian blinds, gates and other single phase, Ac powered devices. Roller Shutter 3 allows precise positioning of roller blinds or venetian blind lamellas. The device is equipped with power and energy monitoring. It allows to control connected devices either via the Z-Wave network or via a switch connected directly to it.
Version #
HW: 3 FW: 5.01:05.01 was the version certified
Certification #
ZC10-22047078
Certified
2022-03-31T10:48:29.710445
Z-Wave Version
6.81.01

Security

As a Z-Wave Plus certified product, Roll-Control supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Authenticated

Features

Nice describes Roll-Control as having the following features:

  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

To remove the device from the Z-Wave network:
1. Make sure the device is powered.
2. Identify the S1 switch.
3. Set the main controller in remove mode (see the controller’s manual).
4. Quickly, triple click the S1 switch.
5. Wait for the removing process to end.
6. Successful removing will be confirmed by the Z-Wave controller’s message.

Factory reset Roll-Control

Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave controller and user
configuration will be deleted.
Note. Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure
only if the primary controller is missing or inoperable. Certain device removal can be achieved by the procedure of removing described in the “Adding the device” section.
Resetting the device to factory defaults:
1. Switch off the mains voltage (disable the fuse).
2. Remove the device from the wall switch box.
3. Switch on the mains voltage.
4. Press and hold the B-button to enter the menu.
5. Wait for the LED indicator to glow yellow.
6. Quickly release and click the B-button again.
7. After few seconds the device will be restarted, which is signalled with the red LED indicator colour

4.1 - Using the manual method
To add the device to the Z-Wave network manually:
1. Power the device.
2. Identify the S1 switch.
3. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
4. Quickly, triple click the S1 switch.
5. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the underlined 5-digit PIN code (label on the side of the
box and on the device).
6. Wait for the adding process to end.
7. Successful adding will be confirmed by the Z-Wave controller’s message.
4.2 - Using the SmartStart method
1. To add the device to the Z-Wave network using SmartStart:
2. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual).
3. Scan the DSK QR code or input the underlined 5-digit PIN code (label on the side of the box and on the device).
4. Power the device (turn on the mains voltage).
5. LED will start blinking yellow, wait for the adding process to end.
6. Successful adding will be confirmed by the Z-Wave controller’s message.

SmartStart location

SmartStart QR code's location as follows: 4.1 - Using the manual method
To add the device to the Z-Wave network manually:
1. Power the device.
2. Identify the S1 switch.
3. Set the main controller in (Security/non-Security Mode) add mode (see the controller’s manual).
4. Quickly, triple click the S1 switch.
5. If you are adding in Security S2 Authenticated, scan the DSK QR code or input the underlined 5-digit PIN code (label on the side of the
box and on the device).
6. Wait for the adding process to end.
7. Successful adding will be confirmed by the Z-Wave controller’s message.
4.2 - Using the SmartStart method
1. To add the device to the Z-Wave network using SmartStart:
2. Set the main controller in Security S2 Authenticated add mode (see the controller’s manual).
3. Scan the DSK QR code or input the underlined 5-digit PIN code (label on the side of the box and on the device).
4. Power the device (turn on the mains voltage).
5. LED will start blinking yellow, wait for the adding process to end.
6. Successful adding will be confirmed by the Z-Wave controller’s message.

Please note that this is a user manual Roll-Control from Nice is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Roll-Control and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.