Overview

Name
Smoke Sensor
SKU Code
PSG01
Description
The Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave™ technology.
It is a Z-Wave™ plus product, it supports the security, OTA... Those newest features of the Z-Wave™ technology. Z-Wave™ is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
Version #
01 was the version certified
Certification #
ZC10-14110003
Certified
2014-11-03T13:36:42.766832
Z-Wave Version
6.51.02

Security

As a Z-Wave Plus certified product, Smoke Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Philio describes Smoke Sensor as having the following features:

    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    1. Have Z-Wave™ Controller entered exclusion mode.
    2. Pressing button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed.

    1. Have Z-Wave™ Controller entered inclusion mode.
    2. Pressing button three times within 1.5 seconds to enter the inclusion mode.
    3. After add successful, the device will wake to receive the setting command from Z-Wave™ Controller about 20 seconds.

    After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds.

    Factory reset Smoke Sensor

    Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.
    1. Pressing button four times within 1.5 seconds and do not release the button in the 4 th pressed, and the red LED will light ON.
    2. After the red LED flash 9 times, release the button within 2 seconds.
    3. IDs are removed and all settings will reset to factory default.

    Please note that this is a user manual Smoke Sensor from Philio is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Smoke Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.