Z-Wave CO Sensor (PSG04) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Z-Wave CO Sensor (PSG04)from Philio. To view other Z-Wave products and manuals from Philio follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Z-Wave CO Sensor
SKU Code
PSG04
Description
The Z-Wave CO Sensor PSG04 is designed to give early warning of high concentration CO by giving off the alarm sounds from its build-in alarm horn, based on Z-WaveTM technology.

It is the Z-WaveTM plus product, it support the security, OTA. Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Version #
HW: 1 FW: 1.02:01.02 was the version certified
Certification #
ZC10-19106770
Certified
2019-10-01T18:48:12.401597
Z-Wave Version
6.81.03

Security

As a Z-Wave Plus certified product, Z-Wave CO Sensor supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Philio describes Z-Wave CO Sensor as having the following features:

  • Firmware updatable via a compatible Z-Wave gateway
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

SmartStart location

SmartStart QR code's location as follows: The QR code can be found on the device PSG04 or in the box.

1. Have Z-WaveTM Controller entered inclusion mode.
2. Pressing button three times within 1.5 seconds to enter the inclusion mode.
3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.

1. Have Z-WaveTM Controller entered exclusion mode.
2. Pressing button three times within 1.5 seconds to enter the exclusion mode.
Node ID has been removed.

When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy.

Factory reset Z-Wave CO Sensor

1. Pressing button four times within 1.5 seconds and do not release the button in the 4th pressed.
2. After 3 secands and release the button within 2 seconds.
3. IDs are removed and all settings will reset to factory default.

Please note that this is a user manual Z-Wave CO Sensor from Philio is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Z-Wave CO Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.