Mold Detector (POPE700878) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Mold Detector (POPE700878)from Popp & Co.. To view other Z-Wave products and manuals from Popp follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Mold Detector
SKU Code
POPE700878
Description
This device measures the three air quality parameters temperature, humidity and dew point an reports them to a central controller. Beside this, the device can directly control groups of other Z-Wave devices on over- and undershooting a set temperature and/or humidity parameter. This can be used to establish control loops for temperature and humidity. The device wakes up every 4 minutes to measure the values and it will send unsolicited reports when values change. Additionally, the device will report all values on request.
The mold detector is actively monitoring the danger of mold in a room based on the temperature and humidity and will issue alarm warnings when critical air conditions met. Wireless Alarm and red and a green blinking LED will indicate a mold condition. This local LED warning function is also available when the device is not included in any Z-Wave network and works stand alone.
Version #
HW: 1 FW: 1.00 was the version certified
Certification #
ZC10-19026384
Certified
2019-02-27T21:58:03.361969
Z-Wave Version
6.81.01

Security

As a Z-Wave Plus certified product, Mold Detector supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Popp describes Mold Detector as having the following features:

  • Battery Quantity
  • Battery powered using 1/AA batteries
  • Color
  • Firmware updatable via a compatible Z-Wave gateway
  • Sensors
  • Supported Notification Types
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Factory reset Mold Detector

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Tripple clicking the tamper button includes (adds) the device.

Tripple clicking the tamper button excludes (removes) the device.

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Once Cover is removed and tamper switch is tripped, push the tamper for 5 seconds until red LED blinks. Then release tamper and push it again for 5 seconds until LED blinks.

A single click on the tamper button will wakeup the device.

Please note that this is a user manual Mold Detector from Popp & Co. is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Mold Detector and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.