Overview

Name
Secure Key Chain Controller
SKU Code
POPE009204
Description
The Secure Key Fob Controller is a 4 button Z-Wave device capable to act both as primary or secondary controller. The four buttons can control other Z-Wave devices such as switches, dimmer and even door locks directly. Various options - configurable by Z-Wave configuration commands - define the actions and the commands used for this control. It is possible to use two sets of buttons (one of on/open/up and one for off/closed/down) or 4 single buttons to control 4 different groups of devices.

The controller also allows triggering scenes in a central controller. Again different modes can be configured to adapt to the various implementations of scenes in different central controllers in the market.

Control options also include special modes like "all on/off" or always controlling the Z-Wave device in proximity to the fob.
Version #
HW: 1 FW: 1.01 was the version certified
Certification #
ZC10-16125340
Certified
2016-12-10T18:51:55.939151
Z-Wave Version
6.51.03

Security

As a Z-Wave Plus certified product, Secure Key Chain Controller supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Popp describes Secure Key Chain Controller as having the following features:

    • Battery Quantity
    • Battery powered using CR2032 batteries
    • Color
    • Z-Wave Scene Type
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    When in factory default push Button 3 (secure) or Button 4 (normal) for one second to enter inclusion mode. The inclusion mode is indicated by a blinking green LED. From second device on you need to enter management mode push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 1 (secure) or button 2 (normal).

    Enter management mode by push all four buttons together for one second - green led blinks slowly), hit button 3 ( enter primary controller functions - green led blinks faster) and then button 3 again.

    Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 2 .

    Factory reset Secure Key Chain Controller

    Enter management mode by push all four buttons together for one second - green led blinks slowly), then hit button 3 followed by keeping button 4 pushed down for 10 seconds. The first five seconds the green LED still blinks followed by a long red, shot green sequence. Once LEDs go off, reset was executed. Please use this
    procedure only if the device is secondary controller and the primary controller is missing or otherwise inoperable.

    When in factory default push Button 1 (secure) or Button 2 (normal) for one second to enter learn mode. The learn mode is indicated by a blinking LEDs red/green. Learn mode will only activate when device is in factory reset state.

    Please note that this is a user manual Secure Key Chain Controller from Popp is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Secure Key Chain Controller and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.