Wall Scene Controller (POPE009303) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Wall Scene Controller (POPE009303)from Popp. To view other Z-Wave products and manuals from Popp follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Wall Scene Controller
SKU Code
POPE009303
Description
The Wall Scene Controller is a Z-Wave device that can both control other Z-Wave devices and activate scenes. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:

Control of groups of other Z-Wave devices using 'ON', 'OFF' and Dim commands. Activation of predefined scenes in Gateways or other Z-Wave devices. This device support secure communication when included by a controller that also supports secure communication.
Version #
HW: 1 FW: 1.01 was the version certified
Certification #
ZC10-16125347
Certified
2016-12-13T20:58:03.518309
Z-Wave Version
6.51.01

Security

As a Z-Wave Plus certified product, Wall Scene Controller supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Popp describes Wall Scene Controller as having the following features:

    • Battery Quantity
    • Battery powered using CR2032 batteries
    • Color
    • Z-Wave Scene Type
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Factory reset Wall Scene Controller

    Use this procedure only if the primary controller is missing or otherwise inoperable.
    (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds.

    (1) Turn the device into Management Mode by keeping all four buttons pushed for 5 seconds, (2) click on Button 2.

    Re-Inclusion and Exclusion are performed by pushing button 1 in management mode. Pushing all four buttons for 5 sec. turns the device into management mode (indicated by blinking green LED).

    Place your primary controller in inclusion mode by following the manufacturer's instructions, then activate inclusion on the wall controller by pressing any one of the four buttons for one second. Inclusion mode is indicated by the red/green blinking of the LEDs until the timeout occurs after 10 seconds.

    Please note that this is a user manual Wall Scene Controller from Popp is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Wall Scene Controller and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.