Flush Dimmer 0-10V (ZMNHVD3) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Flush Dimmer 0-10V (ZMNHVD3)from QUBINO. To view other Z-Wave products and manuals from Qubino follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Qubino Flush Dimmer 0-10V
SKU Code
ZMNHVD3
Description
The Qubino Flush Dimmer 0-10V is a universal dimmer with a standard 0-10V output and a multi-function input, which may be a push button or switch, a potentiometer or a 0-10V signal. It also measures power consumption and supports the connection of a digital temperature sensor.


Version #
HW: 1 FW: 2.03:02.03 was the version certified
Certification #
ZC10-17025448
Certified
2017-02-24T17:10:35.934007
Z-Wave Version
6.51.08

Security

As a Z-Wave Plus certified product, Flush Dimmer 0-10V supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Qubino describes Flush Dimmer 0-10V as having the following features:

    • Switch Type
    • Switch Load Capacity Watts
    • Electric Load Type
    • Sensors
    • Supported Meter Type
    • Color
    • Switch Load Capacity Current
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    • Connect module to power supply (with
    temperature sensor connected - if purchased),
    • enable add/remove mode on main controller
    • auto-inclusion (works for about 5 seconds after connected to power supply) or
    • press service button S for more than 2 second or
    • press push button I1 three times within 3s (3 times change switch state within 3 seconds).

    NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
    NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.

    • Connect module to power supply
    • bring module within maximum 1 meter (3 feet) of the main controller,
    • enable add/remove mode on main controller,
    • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
    • press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.
    By this function all parameters of the module are set to default values and own ID is deleted.
    If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

    NOTE 1: If the module is included with parameter 1 value 3, 4 or 5 and module reset is done, wait at least 30s before next inclusion.

    NOTE 2: Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    Factory reset Flush Dimmer 0-10V

    • Press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
    • press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.

    Please use this procedure only when the network primary controller is missing or otherwise inoperable.

    Please note that this is a user manual Flush Dimmer 0-10V from QUBINO is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Flush Dimmer 0-10V and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.