The following is an overview of the user manual for the Z-Wave product Flush Dimmer (ZMNHDD1)from QUBINO. To view other Z-Wave products and manuals from Qubino follow that link.
Overview
Security
As a Z-Wave Plus certified product, Flush Dimmer supports Z-Wave S2 security. The following security modes are directly supported:
Features
Qubino describes Flush Dimmer as having the following features:
- Color
- Electric Load Type
- Switch Type
- Supported Meter Type
- Sensors
- Switch Load Capacity Current
- Switch Load Capacity Watts
- FLiRS capable
- Supports Network Wide Inclusion
- Supports Z-Wave Explorer Frames
- Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via
Installation instructions
• Connect module to power supply (with
temperature sensor connected - if purchased),
• enable add/remove mode on main controller
• auto-inclusion (works for about 2 minutes after connected to power supply) or
• press push button I1 three times within 3s (3 times change switch state within 3 seconds) or
• press service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.
NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Factory reset Flush Dimmer
• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.
• Connect module to power supply
• bring module within maximum 1 meter (3feet) of the main controller,
• enable add/remove mode on main controller,
• press push button I1 five times within 3s ( 5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
• press service button S (only applicable for 24 V SELV supply voltage) for more than 6 second.
By this function all parameters of the module are set to default values and own ID is deleted.
If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion
Please note that this is a user manual Flush Dimmer from QUBINO is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Flush Dimmer and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.