Energy Meter Reader (2000-0000-15-00) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Energy Meter Reader (2000-0000-15-00)from Quby. To view other Z-Wave products and manuals from Quby follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Energy Meter Reader
SKU Code
2000-0000-15-00
Description
The Energy Meter Reader measures electricity, gas and heat usage of analog and digital energy meters. Analog meters are read by means of optical sensors that can be placed on the energymeter to monitor the rotating disc or the blinking LED. In case of a digital meter, the meter adapter can be connected to the digital meter by means of a P1 digital communication interface. The meter adapter measures the cumulative and instantaneous gas and electricity consumption and sends this information to a Z-Wave enabled display (Quby Energy Display).
Version #
HW: 2 FW: 0.23:00.14:00.00 was the version certified
Certification #
ZC10-16095217
Certified
2016-09-06T13:17:17.495
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Energy Meter Reader supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Quby describes Energy Meter Reader as having the following features:

    • Firmware updatable via a compatible Z-Wave gateway
    • Supported Meter Type
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    To add the Energy Meter Reader into a Z-Wave network, the inclusion process should be started on the controller. In factory default mode, the Energy Meter Reader will try to join a Z-Wave network automatically after being plugged into a power socket. If the Energy Meter Reader was previously included in a Z-Wave network, or was not just plugged into a power socket, one needs to triple-press the button (quickly).

    To remove the Energy Meter Reader from a Z-wave network, the exclusion process should be started on the controller. The button on the Energy Meter Reader should then be triple-pressed (quickly).

    Factory reset Energy Meter Reader

    The Energy Meter Reader can be reset to factory default by pressing and holding the button for approximately 10 seconds. This will reset the entire device to factory default, also removing the Z-Wave set-tings. After the reset is complete, both LEDs will blink a single time (indicating startup). If the device was connected to a Z-Wave net-work, it will no longer be connected after reset.
    Please use this procedure only in the event that the primary controller is missing or otherwise inoperable.

    Please note that this is a user manual Energy Meter Reader from Quby is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Energy Meter Reader and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.