Door Sensor (ZD2105US-5) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Door Sensor (ZD2105US-5)from Raylios. To view other Z-Wave products and manuals from Raylios follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Door Sensor
SKU Code
ZD2105US-5
Description
The ZD2105US-5 Recessed Door sensor can be used in any Z-Wave network, to detect the opening or closing of a door or window. Special Design can fit most door/window frames. This sensor monitors door/window and send Z-Wave™ signal when door or window is opened and closed. Recessed Door Sensors are easily installed inside the door or window frame to keep the sensor hidden from view. When the device is securely included into Z-Wave network, above communication will be encrypted.
Version #
HW: 1 FW: 5.01:10.02 was the version certified
Certification #
ZC10-18015978
Certified
2018-01-23T21:05:53.653483
Z-Wave Version
6.51.06

Security

As a Z-Wave Plus certified product, Door Sensor supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    Raylios describes Door Sensor as having the following features:

    • Supported Notification Types
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    For “Exclusion” from (removing from) a network: Put the Z-Wave™ Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2105 from your controller. Press the Program Switch of ZD2105 for 1 second at least to be excluded. Note: All user and network settings will be cleared and the device reset to factory setting defaults when the device is excluded.

    For “Inclusion” in (adding to) a network: Put the Z-Wave™ Interface Controller into “inclusion” mode, and following its instruction to add the ZD2105 to your controller. To get in the “inclusion” mode, please press the Program Switch of ZD2105 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2105 will go to sleep after 20 seconds.

    Factory reset Door Sensor

    *open the cover to send the Alarm Report and trigger the reed switch (close & open) 10 times in 10 seconds, ZD2105 will send the “Device Reset Locally Notification” command and reset to the factory default.
    * Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable.

    *If the cover of sensor is removed, the tamper switch will send signal according the Status/Signal table, and the LED will go solid and ZD2105 will send “Wake Up Notification” after 10 seconds. If ZD2105 received “Wake Up No More Information” command, the red LED will go off. If ZD2105 did not receive”Wake Up No More Information” command after 10 seconds the red LED will go off.

    *Use “Wake Up” command to set up the awaking time and send the wake up notification to controller. User can use command to change the auto wake up from 10 minutes to 1 week, Interval increment is 3 minutes.

    PowerLevel Control, Battery Votlage Detection(Auto report low battery),OTA function

    Please note that this is a user manual Door Sensor from Raylios is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Door Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.