Remote Temperature and Humidty (RTH100Z) manual for Z-Wave

The following is an overview of the user manual for the Z-Wave product Remote Temperature and Humidty (RTH100Z)from RCS. To view other Z-Wave products and manuals from RCS follow that link.

  1. Overview
  2. Security
  3. Features
  4. Installation instructions

Overview

Name
Remote Temperature and Humidty
SKU Code
RTH100Z
Description
Remote Temperature and Humidity Sensor for HVAC market
Version #
HW: 2 FW: 1.40 was the version certified
Certification #
ZC10-17115888
Certified
2017-11-29T18:25:12.453855
Z-Wave Version
6.51.07

Security

As a Z-Wave Plus certified product, Remote Temperature and Humidty supports Z-Wave S2 security. The following security modes are directly supported:

    Features

    RCS describes Remote Temperature and Humidty as having the following features:

    • Battery Quantity
    • Battery powered using AAA batteries
    • Color
    • Firmware updatable via a compatible Z-Wave gateway
    • Sensors
    • FLiRS capable
    • Supports Network Wide Inclusion
    • Supports Z-Wave Explorer Frames
    • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

    Installation instructions

    Exclusion: Removing the RTH100Z from a Network:

    1. Set your primary controller to Remove mode, to remove the RTH100Z as a node on your network (see your controller’s user manual for detailed instructions).

    2. Press and release the Install button. The controller will indicate the device has been removed from the network.

    3. The device will automatically be restored to its default settings

    To wake-up the device for configuration you can triple-press the install button.

    Inclusion: Including the RTH100Z into an Existing Network:

    1. Set your primary controller to Include mode, to add the RTH100Z as a node on your network (see your controller’s user manual for detailed instructions).

    2. Press and release the Install button. The controller will indicate the device has been included into the network.

    Your controller will indicate the RTH100Z was successfully added to its network (see your controller’s user manual for details). Inclusion and exclusion are always done at normal transmit power mode.

    If your controller supports NWI, then you can optionally set the primary to NWI include mode. Please note that NWI inclusion mode does not end when you have included a new node. This allows multiple nodes to be included without having to physically go back to the controller to initiate the next inclusion. Therefore you must manually terminate NWI inclusion mode at the controller when you have finished including any new nodes to the network. Since intermediate included nodes will assist the inclusion process by routing messages, we recommend that nodes close to the primary controller be installed first, proceeding out in consecutive rings from the controller.

    Note: Consult your controller’s user manual for details on removing a device from a Z-Wave network.

    Factory reset Remote Temperature and Humidty

    Factory Reset To reset the RTH100Z’s configurations and Z-Wave parameters to Factory Settings (Including association groups and scene configurations), and remove the RTH100Z from any Z-Wave network:

    Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable

    1. Hold down the Install button for approximately 10 seconds 2. Release the install button (the RTH100Z will reset all internal configuration including z-wave configurations). The unit will then reset. 3. When the Status LED begins to blink (un-enrolled) the unit has finished restoring configurations is running in normal mode.

    Please note that this is a user manual Remote Temperature and Humidty from RCS is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Remote Temperature and Humidty and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.