Overview

Name
Open/Close Sensor
SKU Code
DN3G6JA082
Description
The Open/Close Sensor is a product for IoT with magnetic sensors and with functions of Z-Wave communication. It can collect sensing data that door open/close by using a magnet. And it sends the data to the gateway.

The Open/Close Sensor has the following general features:
- Z-Wave communication
- Sensing with
Open/Close sensor (detecting the opening and shutting of the door by using a magnet),
Tamper switch.
Version #
HW: 255 FW: 0.84 was the version certified
Certification #
ZC10-18086204
Certified
2018-07-05T23:01:00.12777
Z-Wave Version
6.71.03

Security

As a Z-Wave Plus certified product, Open/Close Sensor supports Z-Wave S2 security. The following security modes are directly supported:

  • S2 Unauthenticated

Features

Sharp Corporation describes Open/Close Sensor as having the following features:

  • Battery Quantity
  • Battery powered using CR123A batteries
  • Supported Notification Types
  • Sensors
  • FLiRS capable
  • Supports Network Wide Inclusion
  • Supports Z-Wave Explorer Frames
  • Supports Z-Wave SmartStart allowing you to setup the product simply by scanning its QR code via

Installation instructions

Factory reset Open/Close Sensor

Press the button over 10 seconds and release.
Please use this procedure only when the network primary controller like the gateway is missing or otherwise inoperable.

Press the button one push and release.
“Wakeup Notification“ will be sent.

-Remove (exclusion)
Set the controller to the status for “Remove”.
Press the button over 3 seconds and release.
LED blinks when “Remove” is completed.

-Add (Inclusion)
Insert a CR123A, and LED blinks.
Set the controller to the status for “Add”.
Press the button over 3 seconds and release.
About “Add” is completed, LED turns off.
(If security include, LED turns off will soon after “Preparing inclusion” process.)
Note) After inclusion completed, this sensor keep waking about 40 seconds, for interview process.
During this time, button operation is disabled.

Please note that this is a user manual Open/Close Sensor from Sharp Corporation is provided as is and without warranty; all information contained herein is provided by the manufacturer or the certifying body. The information provided is for reference only and is not intended to be used as a substitute for professional advice. ZWaveProducts.com only warrants and is only able to support products purchased directly from us. If you have Open/Close Sensor and have not purchased it from us, please contact the manufacturer directly with any further questions you may have.